Johnson Controls Unitary Products
5
632152-CTG-E-0812
— = Not applicable.
MA Modular Air Handlers use Coil Only Ratings.
MA Modular Air Handlers use Coil Only Ratings.
PSC furnaces, such as the TG8S, TGLS, and TG9S, use Coil Only Ratings.
HC6B060F3(C)
AHE60D
24.5
–
1
1160
47.0
30.4
15.00
11.60
2
1835
56.5
40.5
AHV60D
24.5
–
1
1090
45.5
30.2
15.35
20.65
2
1635
54.5
39.0
11.65
MV20D
24.5
FC/MC62D
1
1075
46.5
29.8
15.00
20.80
2
1630
56.0
39.0
11.80
MV20D
24.5
FC64
1
1075
48.0
31.2
15.00
21.60
2
1630
57.5
40.5
12.00
MX20D
24.5
FC/MC62D
1
1390
49.0
33.0
15.00
11.85
2
1795
56.5
40.5
MX20D
24.5
FC64
1
1390
50.5
34.4
15.00
12.15
2
1795
58.5
42.0
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ANSI/AHRI Standard 210/240.
Cooling MBH based on 80 °F entering air temperature, 50% RH (Relative Humidity), and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTUs at 95 °F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTUs during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
COOLING CAPACITY - With Air Handler Coils (Continued)
UNIT MODEL
AIR HANDLER
COIL
1
MODEL
COOLING
MODEL
WIDTH
STAGE
RATED
CFM
NET MBH
SEER
EER
TOTAL
SENS.
16 SEER HP WITH AIR HANDLERS
COOLING CAPACITY - With Upflow, Downflow, & Horizontal Furnaces and Coils (Coil Only Ratings)
UNIT
MODEL
COIL
CFM RANGE
(MIN.-MAX.)
STAGE
COOLING
MODEL
WIDTH
RATED
CFM
NET MBH
SEER
1
EER
TOTAL
SENS.
16 SEER HP COIL ONLY RATINGS
HC6B024F3(C)
FC/MC/PC32
14.5
600 - 1000
–
800
23.2
17.2
13.35
11.50
FC/MC/PC35
17.5,21.0
600 - 1000
–
800
23.2
17.2
13.35
11.50
FC/MC/PC37
14.5
600 - 1000
–
800
23.6
17.5
13.35
11.50
FC/MC/PC43
17.5,21.0
600 - 1000
–
800
23.6
17.5
13.35
11.50
HC6B030F3(C)
FC/MC/PC37
14.5
800 - 1200
–
1000
28.4
21.4
14.00
12.00
FC/MC/PC43
17.5,21.0
800 - 1200
–
1000
28.4
21.4
14.00
12.00
HC6B036F3(C)
FC/MC/PC48
21.0,24.5
1000 - 1400
–
1200
34.4
25.6
13.35
11.50
FC/MC/PC60
21.0,24.5
1000 - 1400
–
1200
34.0
25.4
13.35
11.50
UC48
21.0,24.5
1000 - 1400
–
1200
34.4
25.6
13.25
11.35
UC60
21.0,24.5
1000 - 1400
–
1200
34.0
25.2
13.25
11.35
HC6B042F4(C)
FC/MC/PC60
21.0.0,24.5.5
1200 - 1600
–
1200
38.5
27.0
13.25
11.35
FC/MC62
24.5.5
1200 - 1600
–
1400
39.0
28.0
13.00
11.00
UC60
21.0,24.5
1200 - 1600
–
1200
38.5
27.4
13.25
11.35
HC6B048F3(C)
FC/MC62
24.5
1400 - 1800
–
1600
46.0
34.4
13.35
11.50
FC64
24.5
1400 - 1800
–
1600
47.0
35.6
13.35
11.50
HC6B060F3(C)
FC/MC62
24.5
1150 - 1550
1
1350
48.0
31.8
15.00
11.10
1600 - 2000
2
1800
55.5
39.5
FC64
24.5
1150 - 1550
1
1350
49.5
33.2
15.00
11.40
1600 - 2000
2
1800
57.5
41.5
1. Requires a S1-2FD06700224 Blower Time Delay unless a standard furnace is equipped with one.