Subject to change without notice. Published in U.S.A.
632152-CTG-E-0812
Copyright © 2012 by Johnson Controls, Inc. All rights reserved.
Supersedes:
632152-CTG-D-0512
York International Corp.
5005 York Drive
Norman, OK 73069
Multipliers for determining the performance with other indoor sections.
HEATING PERFORMANCE DATA - HIGH CFM 2-STAGE OPERATION
OUTDOOR UNIT MODEL NO.
HC6B060F3(C)
INDOOR COIL MODEL NO.
FC/MC62
AIR TEMP.
ENTERING
OUTDOOR UNIT
AIR TEMP.
ENTERING
INDOOR COIL
ID CFM
1650
1850
2050
MBH
COP
KW
MBH
COP
KW
MBH
COP
KW
60
60
72.6
4.30
4.94
73.3
4.42
4.86
74.1
4.55
4.77
70
71.1
3.82
5.45
72.0
3.94
5.36
72.9
4.07
5.25
80
69.6
3.42
5.97
70.7
3.54
5.85
71.7
3.67
5.73
47
60
62.5
3.91
4.68
62.9
3.98
4.63
63.4
4.06
4.58
70
61.4
3.46
5.20
61.9
3.54
5.12
62.4
3.62
5.05
80
60.3
3.10
5.70
60.8
3.18
5.61
61.4
3.26
5.52
40
60
56.0
3.56
4.61
56.4
3.64
4.54
56.7
3.71
4.48
70
55.1
3.17
5.09
55.4
3.23
5.03
55.8
3.30
4.95
80
54.2
2.85
5.57
54.5
2.90
5.51
54.9
2.96
5.44
30
60
47.1
3.16
4.37
46.0
3.10
4.35
45.0
3.04
4.33
70
47.6
2.87
4.86
47.2
2.86
4.83
46.7
2.85
4.80
80
48.2
2.63
5.37
48.3
2.66
5.32
48.5
2.70
5.26
17
60
39.8
2.74
4.26
40.2
2.78
4.24
40.6
2.82
4.22
70
37.9
2.37
4.69
37.8
2.40
4.62
37.7
2.42
4.57
80
36.0
2.07
5.10
35.4
2.07
5.02
34.9
2.07
4.93
10
60
35.0
2.46
4.17
35.2
2.48
4.16
35.4
2.50
4.15
70
34.7
2.23
4.57
34.9
2.25
4.55
35.1
2.28
4.51
80
34.4
2.03
4.97
34.6
2.06
4.93
34.8
2.09
4.89
NOTE:
ALL CAPACITIES ARE NET, WITH INDOOR FAN HEAT ALREADY DEDUCTED. KW VALUES ARE FOR THE SYSTEM (O INDOOR).
Air Handler
Coil
MBH
COP
KW
–
FC/MC62D
1.00
1.00
1.00
–
FC64
1.04
1.05
0.99
AHE60D
–
1.00
1.03
0.97
AHV60D
–
0.98
1.00
0.97
MV20D
FC/MC62D
0.98
1.00
0.98
MV20D
FC64
0.99
0.99
1.01
MX20D
FC/MC62D
1.01
0.99
1.02
MX20D
FC64
1.04
0.99
1.04
Furnace
Coil
MBH
COP
KW
T*(8,L)V*C16
FC/MC62D
0.99
1.03
0.96
T*(8,L)V*C16
FC64
1.00
1.01
0.99
T*(8,L)V*C20
FC/MC62D
0.99
1.02
0.97
T*(8,L)V*C20
FC64
0.99
1.00
0.99
T*(8,L)X*C16
FC/MC62D
0.99
1.02
0.97
T*(8,L)X*C16
FC64
0.99
0.99
1.00
T*(8,L)X*C20
FC64
0.99
0.98
1.01
T*9(C,V)*C16
FC/MC62D
0.99
1.04
0.96
T*9(C,V)*C16
FC64
1.00
1.02
0.98
T*9(C,V)*C20
FC/MC62D
1.00
1.05
0.95
T*9(C,V)*C20
FC64
1.00
1.02
0.98
T*9(C,V)*D20
FC/MC62D
0.99
1.04
0.96
T*9(C,V)*D20
FC64
1.00
1.02
0.98
T*9X*C16
FC/MC62D
0.99
1.02
0.97
T*9X*C16
FC64
0.99
1.00
0.99
T*9X*C20
FC/MC62D
0.98
1.02
0.97
T*9X*C20
FC64
0.99
1.00
0.99
T*9X*D20
FC/MC62D
0.99
1.03
0.96
T*9X*D20
FC64
0.99
1.00
0.99
C*(8,L)C*C16
FC/MC62D
0.99
1.03
0.96
C*(8,L)C*C16
FC64
1.00
1.01
0.99
C*(8,L)C*C20
FC/MC62D
0.99
1.02
0.97
C*(8,L)C*C20
FC64
0.99
1.00
0.99
C*9C*C16
FC/MC62D
0.99
1.04
0.96
C*9C*C16
FC64
1.00
1.02
0.98
C*9C*C20
FC/MC62D
1.00
1.05
0.95
C*9C*C20
FC64
1.00
1.02
0.98
C*9C*D20
FC/MC62D
0.99
1.04
0.96
C*9C*D20
FC64
1.00
1.02
0.98
Furnace
Coil
MBH
COP
KW