18
Johnson Controls Unitary Products
632152-CTG-E-0812
* Notates “Hot Heat Pump” performance. These ratings are not AHRI Listed.
COP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input
during the same period.
— = Not Applicable.
PSC furnaces, such as the TG8S, TGLS, and TG9S, use Coil Only Ratings.
HC6B042F4(C)
C*(8,L)C*C20
FC/MC62D
1365
40.5
4.06
2.92
25.8
2.74
2.76
8.50
C*(8,L)C*C20
FC/PC60C
1215
41.0
4.08
2.94
25.8
2.80
2.70
8.50
970*
40.0
3.86
3.04
25.2
2.74
2.69
8.98
C*(8,L)C*C20
UC60C
1215
41.0
4.00
3.00
25.4
2.72
2.74
8.50
970*
40.0
3.80
2.86
25.1
2.84
2.66
8.20
C*9C*C16
FC/MC62D
1445
41.0
4.00
3.00
26.2
2.68
2.86
8.20
C*9C*C16
FC/PC60C
1235
41.0
4.02
2.99
26.0
2.74
2.78
8.20
1020*
40.0
3.82
3.07
25.4
2.72
2.74
8.48
C*9C*C16
UC60C
1235
41.0
3.90
3.08
25.6
2.68
2.80
8.20
1020*
40.0
3.82
3.07
25.4
2.72
2.74
8.48
C*9C*C20
FC/MC62D
1445
41.0
4.06
2.96
26.0
2.72
2.80
8.20
C*9C*C20
FC/PC60C
1330
41.5
4.08
2.98
26.0
2.76
2.76
8.20
980*
40.0
3.84
3.05
25.4
2.74
2.72
8.48
C*9C*C20
UC60
1330
41.5
4.02
3.02
25.6
2.70
2.78
8.20
980*
40.0
3.84
3.05
25.4
2.74
2.72
8.48
C*9C*D20
FC/MC/PC60D
1225
41.0
4.06
2.96
25.8
2.78
2.72
8.50
1075*
40.0
3.94
2.97
25.4
2.76
2.70
8.98
C*9C*D20
FC/MC62D
1455
41.0
4.08
2.94
25.8
2.74
2.76
8.20
1235*
40.0
3.96
2.96
25.6
2.74
2.74
8.98
C*9C*D20
UC60C
1225
41.0
3.96
3.03
25.6
2.70
2.78
8.20
1235*
40.0
3.74
2.89
25.3
2.82
2.68
8.50
HC6B048F3(C)
T*(8,L)V*C16
FC64
1635
48.0
3.86
3.87
34.4
2.72
3.71
9.00
1000*
48.0
3.37
4.33
34.4
2.72
3.71
9.00
T*(8,L)V*C20
FC64
1630
48.0
3.88
3.85
34.2
2.74
3.66
9.00
1000*
48.0
3.39
4.31
34.2
2.74
3.66
9.00
T*(8,L)X*C16
FC64
1610
48.0
3.90
3.83
34.2
2.76
3.63
9.00
1000*
48.0
3.41
4.29
34.2
2.76
3.63
9.00
T*(8,L)X*C20
FC/MC62D
1665
48.0
3.84
3.89
33.8
2.70
3.67
9.00
1200*
48.0
3.43
4.29
33.8
2.70
3.67
9.00
T*(8,L)X*C20
FC64
1665
48.0
3.92
3.81
34.0
2.76
3.61
9.00
1200*
48.0
3.51
4.21
34.0
2.76
3.61
9.00
T*9(C,V)*C16
FC64
1590
48.0
3.84
3.93
34.4
2.72
3.71
9.00
1000*
48.0
3.35
4.39
34.4
2.72
3.71
9.00
T*9X*C20
FC/MC62D
1595
48.0
3.76
3.94
33.6
2.68
3.67
9.00
1200*
48.0
3.35
4.34
33.6
2.68
3.67
9.00
T*9X*C16
FC64
1550
48.0
3.88
3.85
34.2
2.74
3.66
9.00
1000*
48.0
3.39
4.31
34.2
2.74
3.66
9.00
T*9X*C20
FC64
1595
48.0
3.92
3.81
34.0
2.76
3.61
9.00
1200*
48.0
3.51
4.21
34.0
2.76
3.61
9.00
T*9X*D20
FC64
1610
48.0
3.88
3.85
34.2
2.74
3.66
9.00
1200*
48.0
3.47
4.25
34.2
2.74
3.66
9.00
C*(8,L)C*C16
FC64
1635
48.0
3.86
3.87
34.4
2.72
3.71
9.00
1000*
48.0
3.37
4.33
34.4
2.72
3.71
9.00
C*(8,L)C*C20
FC64
1630
48.0
3.88
3.85
34.2
2.74
3.66
9.00
1000*
48.0
3.39
4.31
34.2
2.74
3.66
9.00
C*9C*C16
FC64
1590
48.0
3.84
3.93
34.4
2.72
3.71
9.00
1000*
48.0
3.35
4.39
34.4
2.72
3.71
9.00
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. Heating MBH based on AHRI standards of 70 °F DB (Dry Bulb) entering indoor air, 72% RH (Relative Humidity) outdoor air with 25 feet of interconnecting piping
and no supplemental electric heat operation.
3. High Efficiency Motor Furnaces have B.O.D (Blower on Delay) standard.
HEATING CAPACITY - With High Efficiency Motor Furnaces (Continued)
UNIT
MODEL
FURNACE
MODEL
COIL
1
MODEL
HEATING
2
RATED
CFM
47
F
17
F
HSPF
MBH
COP
KW
MBH
COP
KW
STD
16 SEER HP WITH HIGH EFFICIENCY MOTOR FURNACES
3