background image

OPERATING INSTRUCTIONS MANUAL

THC- 355CDF

(Dual Fuel)

INDUSTRIAL / COMMERCIAL DIRECTIONAL SPACE HEATER

(OPERATOR MUST RETAIN FOR  FUTURE REFERENCES)

Certified to / Certifié à ANSI std Z83.7 2000

Certified to / Certifié à CGA 2.14 M2000

Suitable for indoor or outdoor installation / Unvented / Unattended Type

26 Benfield Drive, St.Catharines, Ontario Canada L2S 3V5  

(P) 905-685-4243 - (F) 905-685-0113

1

                  ISSUE DATE: OCTOBER 2010

Summary of Contents for THC- 355CDF

Page 1: ...RATOR MUST RETAIN FOR FUTURE REFERENCES Certified to Certifié à ANSI std Z83 7 2000 Certified to Certifié à CGA 2 14 M2000 Suitable for indoor or outdoor installation Unvented Unattended Type 26 Benfield Drive St Catharines Ontario Canada L2S 3V5 P 905 685 4243 F 905 685 0113 1 ISSUE DATE OCTOBER 2010 ...

Page 2: ...TIONS SHOULD USE OR SERVICE THIS HEATER IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS MANUAL LABEL ETC CONTACT THE MANUFACTURER WARNING FIRE BURN INHALATION AND EXPLOSION HAZARD KEEP SOLID COMBUSTIBLES SUCH AS BUILDING MATERIALS PAPER OR CARDBOARD A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY THE INSTRUCTIONS NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VO...

Page 3: ...pane Installation Code CSA B149 5 This heater must be installed by a qualified gas technician following local codes published by the authority having jurisdiction The installation of this heater for use with propane tank or cylinder shall conform with local codes or in the absence of local codes with the Standard for the Storage and Handling of Liquefied Petroleum Gases ANSI NFPA 58 and the Natura...

Page 4: ...ollowing local codes published by the authority having jurisdiction Sizing of supply piping must be determined using the length of pipe run as well as total btuh rating of the appliance s Appropriate piping tables must be used to determine size of supply piping dependant on the length of run from source PRESSURES MIN MAX LP INLET PRESSURE 11 IN WC 14 IN WC NG INLET PRESSURE 9 0 IN WC 14 IN WC This...

Page 5: ...ate gauge extension cord is used CLEARANCE TO COMBUSTIBLES TOP 5 ft FRONT 2 ft SIDES 1 ft REAR 2 ft POWER SUPPLY INDICATOR LIGHT The power supply indicator light will help detect any faulty power supplied to the heater such as grounding issues reverse polarity or missing poor connections Warning Light Indications Green Light Meets Power Requirements Solid Red Light Reverse Polarity Solid Red Green...

Page 6: ... be obstructed Be sure to check the fan assembly and ensure the motor and blade are operating properly 5 Compressed air may be used to keep components free of dust and dirt build up Note Do not use the compressed air inside any piping or regulator components START UP INSTRUCTIONS 1 For LP Connect the POL inlet on the regulator of the heater to the propane cylinder For NG Ensure the Heater is provi...

Page 7: ...ve Burner switch to OFF position 3 Wait 2 3 minutes and move FAN switches to the OFF position 4 Disconnect heater from fuel supply Important Note When heater is to be stored indoors the connection between the propane supply cylinder s and the heater must be disconnected and the cylinder s removed from the heater and stored in accordance with CSA B149 5 Natural Gas and Propane Installation Code ANS...

Page 8: ...14 WC BURNER MANIFOLD PRESSURE 7 75 WC 5 5 WC FUEL CONSUMPTION PER HR 16 0 LBS 307 CFH TEMPERATURE RISE above ambient 160 F 150 F AMP DRAW STARTING 21 AMPS CONTINUOUS 7 AMPS OUTLET SIZE 12 5 X 10 75 Designed for 18 Dia Ducting DIMENSIONS 42 X 46 X 32 5 H X L X W IN SHIPPING WEIGHT 390 LBS IGNITION Direct Spark Ignition Thermostat Control AIR CIRCULATION 2400 CFM APPROVED cETLus listed 7 ...

Page 9: ...d proper rear clearances are maintained see for specifications rear of appliance Carefully open the panel If the rear of the heater is The high temperature switch reset obstructed the snap disc button is found behind the louvers manual reset limit may trip on the rear of the heater and must be reset manually DISCONNECT THE POWER TO before the burner can operate THE HEATER Reach around the protecti...

Page 10: ...oid is energized use volt meter to measure Ensure plunger in solenoid is being activated use manometer at the test point after solenoid Igniter Flame sensor Ensure the gap between the igniter Adjust this side only and sensor is approx 1 8 3 16 DO NOT adjust the porcelain side of the igniter or permanent damage may result Check igniter wire connections Ensure igniter spark is strong Replace igniter...

Page 11: ... heat if it is the fan will start Please note that as a safety measure the thermostat is equipped with a 10 second delay Optional Thermostat If your appliance is equipped with an optional external thermostat check that connections are secure and restart the appliance If the appliance fails to restart remove the optional line thermostat and restart the appliance to confirm its operational status If...

Page 12: ...ed Green Solid Light Ground Issue Thermostat Ensure thermostat is calling for heat NOTE if the thermostat is not calling for heat the appliance will not operate Electrical All Components Before replacing any components all connections must be checked to ensure electrical circuit is complete Use volt meter and enclosed wiring diagram Piping All pipe fittings When loosenEd tightened or replaced the ...

Page 13: ...ER THCP 119A AIR PROVING SAIL SWITCH THCP 110B FAN BLADE THCP 114B IGNITER FLAME SENSOR ASSEMBLY THCP 102 BURNER THCP 101 IGNITOR WIRE THCP 103A 120 24V TRANSFORMER THCP 104 ORIFICE THCP 115AC BURNER FAN SWITCH THCP 111 GAS VALVE SOLENOID 24V THCP 105A IGNITION BOARD THCP 106A WIRING HARNESS THCP 107A POWER CORD THCP 121A ...

Page 14: ...124B TWO STAGE REGULATOR C W POL THCP 129B DOOR LATCH THCP 131A DOOR HINGE THCP 132 BELT TENSIOR THCP 146 BELT TENSIOR PULLEY THCP 147 BELT TENSIOR PULLEY BUSHING THCP 148 MOTOR PULLEY THCP 149 SHAFT PULLEY THCP 150A PILLOW BLOCK THCP 151 X 16 PULLEY SHAFT THCP 152 DRIVE BELT THCP 153 POWER SUPLY INDICATOR THCP 154A ...

Page 15: ...THC 355CDF PARTS LIST FUEL SELECTOR VALVE THCP 155 SIGHT GLASS THCP 162 THERMOSTAT HOLDER THCP 165 20 FT CORD THCP TH CORD THERMOSTAT C W 20 FT CORD THCP TH THERMOSTAT KNOB TH KNOB PULLEY GUARD THCP 164 ...

Page 16: ...F THCP 114B FAN BLADE THC 355DF THCP 115AC ORIFICE FOR THC 355DF THCP 119A ORIFICE HOLDER FOR THC 355DF THCP 121A POWER CORD FOR THC 355DF THCP 122 SIDE HANDLES EACH TWO REQUIRED THCP 124C FLAT FREE WHEEL 12 EACH THCP 124B 6 LOCKABLE CASTERS EACH TWO REQUIRED THCP 125LB WHEEL SHAFT THC 355DF THCP 128B 3 4 X 15 FT HOSE ASSEMBLY 3 4 F JIC X 1 2 MP FOR THC 355DF THCP 129B TWO STAGE REGULATOR 1 2 Outl...

Page 17: ...OW 40 113E5 3 4 X 5 NIPPLE 40 113D1 5 1 2 X 1 1 2 NIPPLE 40 116 8 1 2 90 DEGREE STREET ELBOW EACH TWO REQUIRED 40 120 12 8 3 4 X 1 2 REDUCING BUSHING 348 12E 3 4 MP X 3 4 M JIC STEEL ADAPTER THCP 162 SIGHT GLASS THCP 163 SHAFT MOUNTING BRACKET THC 355CDF THCP 164 PULLEY GUARD THC 355CDF THCP 165 THERMOSTAT HOLDER ALL THC MODELS THCP TH CORD 20FT THERMOSTAT CORD TH KNOB THERMOSTAT KNOB ACCESSORIES ...

Page 18: ...m SI THC 001SI FAN MOTOR FAN SWITCH BURNER SWITCH 120v 24v TRANSFORMER HI LIMIT HI LIMIT AIR PROVING SWITCH IGNITION CONTROL GAS VALVE L1 BLACK N WHITE G GROUND 120 volt 24 volt IGNITER FLAME SENSOR PURPLE BROWN WHITE BLACK YELLOW SMART INDICATOR THC SERIES WIRING DIAGRAM 2010 B W G ...

Reviews: