Johnson Controls Unitary Products
632152-CTG-E-0812
* Adapter fitting required for 1-1/8” line set.
Overall height is from bottom of base pan to top of fan guard.
Overall length and width include screw heads.
Physical and Electrical Data
Model
HC6B024F3(C)
HC6B030F3(C)
HC6B036F3(C)
HC6B042F4(C)
HC6B048F3(C)
HC6B060F3(C)
Unit Supply Voltage
208-230V, 1
60Hz
Normal Voltage Range
1
187 to 252
Minimum Circuit Ampacity
17.5
17.3
22.6
23.7
26.9
33.8
Max. Overcurrent Device Amps
2
30
30
35
40
45
50
Min. Overcurrent Device Amps
3
20
20
25
25
30
35
Compressor Type
Scroll
Scroll
Scroll
Scroll
Scroll
2-Stage Scroll
Compressor Amps
Rated Load
13.4
12.8
17
17.9
20.5
26
Locked Rotor
58.3
64
77
112
115
118
Crankcase Heater
No
No
No
No
No
No
Factory External Discharge Muffler
Yes
Yes
Yes
Yes
Yes
Yes
Factory External Check Valve
No
No
No
No
No
No
HS Kit Required with TXV
4
No
No
No
No
No
No
Fan Motor Amps
Rated Load
0.7
1.3
1.3
1.3
1.3
1.3
Fan Diameter Inches
24
24
24
24
24
24
Fan Motor
Rated HP
1/8
1/4
1/4
1/4
1/4
1/4
Nominal RPM
1075
850
850
850
850
850
Nominal CFM
2750
3800
3800
3800
3400
3700
Coil
Face Area Sq. Ft.
20.6
23.6
23.6
23.6
23.6
23.6
Rows Deep
1
1
1
1
2
2
Fins / Inch
22
22
22
22
22
14
Liquid Line Set OD (Field Installed)
3/8
3/8
3/8
3/8
3/8
3/8
Vapor Line Set OD (Field Installed)
3/4
3/4
3/4
7/8
7/8
1-1/8
Unit Charge (Lbs. - Oz.)
5
9 - 3
9 - 13
10 - 10
11 - 7
14 - 5
14 - 11
Charge Per Foot, Oz.
0.68
0.68
0.68
0.70
0.70
0.76
Operating Weight Lbs.
199
228
230
237
283
298
1. Rated in accordance with AHRI Standard 110-2012, utilization range “A”.
2. Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent protection.
3. Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent protection.
4. See Hard Start Kit Accessory Installation Manual for Hard Start Kit part number for each model.
5. The Unit Charge is correct for the outdoor unit, smallest matched indoor unit, and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, add or
subtract the amount of refrigerant, using the difference in length multiplied by the per foot value.
VAPOR
LIQUID
2-3/8
3-1/8 6-1/2
C
A
B
Unit
Model
Dimensions
(Inches)
Refrigerant Connection
Service Valve Size
A
B
C
Liquid
Vapor
024
40
37
31
3/8
3/4
030
40
42-1/4
34
036
40
42-1/4
34
042
40
42-1/4
34
7/8
048
40
42-1/4
34
060
40
42-1/4
34
7/8*