Johnson Controls Unitary Products
21
632152-CTG-E-0812
ACCESSORIES
TXV Kits -
S1-1TVM series thermal expansion valves precisely
meter refrigerant for optimum performance over a wide range of
conditions. See System Charge table for TXV part number for
each model.
Start Assist Kit (S1-2SA067)
-
Provides increased starting
torque for areas with low voltage. See Hard Start Kit Accessory
Installation Manual for Hard Start Kit part number for each
model.
Temperature Sensor (S1-37309243000) -
The temperature
sensor is used to sense plenum temperature, and is optional
with a gas or oil back-up heat source. Compatible only with 13
SEER and higher heat pumps.
Dehumidistat (S1-2HU16700124) -
Provides increased dehu-
midification when matched with variable speed furnace or air
handler.
Heat Pump Risers (S1-52635389000, S1-52635390000,
S1-52635391000)
-
3", 6", or 12" risers mount easily in compos-
ite base pan recesses, ensuring the unit stays clear of snow
and ice build-up in harsh winter weather.
Thermostats -
Compatible thermostat controls are available
through accessory sourcing. For optimum performance, these
outdoor units are fully compatiable with the
Residential Touch
Screen Communicating Control S1-TTSCC01
.
SOUND POWER LEVEL - TYPICAL OCTAVE BAND SPECTRUM (without tone adjustment)
Rated in accordance with ARI Standard 270.
TYPICAL INSTALLATION
Size
Test Condition
63
125
250
500
1000
2000
4000
8000
dBA
SQI
24
Cooling Mode
72
76
69
67
67
62
58
53
71
19.1
Heating Mode
71
79
70
68
67
62
58
55
71
19.0
30
Cooling Mode
73
70
67
68
69
61
55
48
71
19.1
Heating Mode
76
72
69
69
66
61
57
60
71
19.1
36
Cooling Mode
75
79
70
69
67
61
56
49
72
19.1
Heating Mode
71
80
64
61
62
58
54
53
68
19.0
42
Cooling Mode
70
69
72
68
68
60
55
47
71
19.0
Heating Mode
70
71
72
67
64
60
55
48
70
19.2
48
Cooling Mode
77
78
72
70
66
61
56
50
72
19.1
Heating Mode
75
82
73
72
66
61
58
54
73
19.1
60
Cooling Mode - Stage 1
75
75
70
68
64
61
56
50
70
19.2
Heating Mode - Stage 1
75
76
69
68
66
60
56
51
70
19.1
60
Cooling Mode - Stage 2
73
78
69
68
64
61
56
50
70
19.2
Heating Mode - Stage 2
72
81
70
69
66
63
58
51
72
19.2
THERMOSTAT
NEC CLASS 1
WIRING
TO INDOOR
BLOWER
NEC CLASS 2
WIRING
TO COIL
WEATHERPROOF
DISCONNECT
SWITCH
24” SERVICE
ACCESS
CLEARANCE
ALL OUTDOOR WIRING MUST BE WEATHERPROOF
MINIMUM 24” UNIT TO UNIT CLEARANCE
SEAL OPENINGS WITH
PERMAGUM OR EQUIVALENT
60” OVERHEAD
CLEARANCE
10” CLEARANCE
AROUND PERIMETER
NOTES: