background image

TECHNICAL GUIDE

ECHELON

TM

 SERIES

SPLIT-SYSTEM HEAT PUMPS

16 SEER – R-410A – 1 PHASE

2 THRU 5 NOMINAL TONS

MODELS: HC6B024 THRU 060

Due to continuous product improvement, specifications
are subject to change without notice.

Visit us on the web at 

www.upgnet.com

 

and www.colemanac.com

Additional rating information can be found at 

www.ahridirectory.org

WARRANTY SUMMARY*

Extended 10-Years limited parts warranty.
Extended Lifetime limited compressor warranty.

Extended parts and compressor warranties

 require online

registration within 90 days of purchase for replacement or
closing for new home construction.

* Does not apply to R-22 models, 3-Phase models, or internet sales.
See Limited Warranty certificate in User's Information Manual for details.

®

632152-CTG-E-0812

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

DESCRIPTION

The 16 SEER Series unit is the outdoor part of a versatile climate
system. It is designed with a matching indoor coil component from
Johnson Controls Unitary Products. Available for typical applica-
tions, this climate system is supported with accessories and docu-
ments to serve specific functions.

FEATURES

Superior Coil Protection - 

A stamped, decorative metal coil

guard protects the tube-in-fin coil from debris and other damag-
ing material.

Protected Compressor - 

The compressor is safeguarded

against abnormal pressures and temperatures by an internal
pressure relief valve, an internal temperature sensor, and fac-
tory high and low pressure system controls. A factory installed
liquid line filter-drier further protects the compressor against
moisture and debris.

Environmentally Friendly Refrigerant - 

The next generation

refrigerant R-410A delivers environmentally friendly perfor-
mance with zero ozone depletion.

Durable Finish - 

An automotive quality finish provides the ulti-

mate protection from harmful UV rays and rust creep, ensuring
a long-lasting, high quality appearance. A powder-paint topcoat
is applied over a baked-on primer using a galvanized, zinc
coated steel base material. The result is a finish that has been
proven in testing to provide 33% greater durability than conven-
tional powder-coat finishes.

Hot Heat Pump - 

An optional mode that slows the indoor fan

for higher register air temperatures and premium comfort.

WhisperDrive™ System - 

Features combination of swept-

wing fan, composite base pan, isolated compressor compart-
ment, and single-stage compressor to reduce overall sound to
a mere whisper. The 5-ton system utilizes a two-stage com-
pressor.

Low RPM Fan Motor - 

Helps to reduce airflow noise.

Swept Wing Fan - 

A fan design boasting technology adapted

from aeronautic and defense engineering provides for whisper-
quiet operation by allowing air to flow smoothly and efficiently
across the fan tips.

Composite Base Pan - 

The strong and durable composite

base pan provides added strength while resisting rust and cor-
rosion, as well as reducing sound and vibration.

Isolated Compressor Compartment - 

A molded composite

bulkhead isolates the refrigeration components and the com-
pressor from the rest of the unit, reducing sound and vibration.

Lower Installed Cost - 

Designed to provide enhanced instal-

lability by featuring a slide-down control compartment that
allows easy access to control components, along with angled
service valves to reduce overall installation time and cost. Fac-
tory charged for a 15 foot lineset.

Factory Installed Filter-Drier - 

A factory installed, solid core

liquid line filter-drier removes harmful debris and moisture from
the system.

Easy Service Access - 

A full end, full service access panel

with handle makes for easy entry to internal components.

Communications Capable - 

Requiring only a simple 4-wire

installation, the communicating capability enables the use of
the Touch Screen Communicating Control, allowing real time
visibility of system operation and the use of diagnostic features,
while still maintaining the ability to function with a traditional
thermostat. 

Complete System Control - 

These heat pumps utilize a

unique microprocessor defrost control system to provide opti-
mal comfort as well as monitor the overall system for reliable
operation. In the event improper operating conditions occur
(high temperature and/or high pressure), the system will auto-
matically shut the system down to extend the life of the heat
pump. The defrost control features an internal memory to aid
the technician in troubleshooting, reducing service time and
cost.

Premium System Warranty* - 

Limited lifetime compressor

warranty when registered online within 90 days of installation. 

Agency Listed - 

Safety certified by CSA to UL 1995 / CSA

22.2. Performance certified to ANSI/AHRI Standard 210/240 in
accordance with the Unitary Small Equipment certification pro-
gram.

Summary of Contents for HC6B024 THRU 060

Page 1: ...omfort WhisperDrive System Features combination of swept wing fan composite base pan isolated compressor compart ment and single stage compressor to reduce overall sound to a mere whisper The 5 ton sy...

Page 2: ...minal CFM 2750 3800 3800 3800 3400 3700 Coil Face Area Sq Ft 20 6 23 6 23 6 23 6 23 6 23 6 Rows Deep 1 1 1 1 2 2 Fins Inch 22 22 22 22 22 14 Liquid Line Set OD Field Installed 3 8 3 8 3 8 3 8 3 8 3 8...

Page 3: ...42D TXV 0 AHE48D TXV 20 TXV 0 AHE60D TXV 5 TXV 0 TXV 0 AHR24B TXV 0 AHR36B TXV 0 AHR42C TXV 0 AHR60D TXV 0 TXV 0 AHV24B TXV 0 AHV30B TXV 0 AHV36C TXV 12 TXV 0 AHV42D TXV 0 AHV48D TXV 20 TXV 0 AHV60D T...

Page 4: ...26 6 15 00 12 50 AHR42C 21 0 1230 34 6 28 2 13 35 11 50 AHV42D 24 5 1180 35 4 27 0 15 00 12 50 AHV48D 24 5 1155 35 2 26 6 15 00 12 50 AV 48 24 5 1220 35 2 26 6 15 00 12 50 MV12D 24 5 FC MC48D 1160 34...

Page 5: ...G CAPACITY With Air Handler Coils Continued UNIT MODEL AIR HANDLER COIL1 MODEL COOLING MODEL WIDTH STAGE RATED CFM NET MBH SEER EER TOTAL SENS 16 SEER HP WITH AIR HANDLERS COOLING CAPACITY With Upflow...

Page 6: ...C PC37A 790 23 6 17 7 14 00 12 00 T 9X A10 14 5 FC MC PC32A 745 23 2 17 0 14 55 12 00 T 9X A10 14 5 FC MC PC37A 740 23 4 17 2 14 75 12 00 T 9X B12 17 5 FC MC PC35B 785 23 8 17 7 15 00 12 50 T 9X B12 1...

Page 7: ...V D20 24 5 FC MC PC48D 1240 35 0 26 6 15 00 12 50 T 9 C V D20 24 5 FC MC PC60D 1225 35 0 26 4 15 00 12 50 T 9X C16 21 0 FC MC PC48C 1280 35 2 27 0 15 00 12 50 T 9X C16 21 0 FC PC60C 1315 35 4 27 4 15...

Page 8: ...39 0 27 6 15 00 12 50 C 8 L C C16 21 0 UC60C 1195 39 0 27 8 15 00 12 50 C 8 L C C20 21 0 FC MC62D 1365 39 5 28 4 14 50 12 00 C 8 L C C20 21 0 FC PC60C 1215 39 5 28 4 15 00 12 50 C 8 L C C20 21 0 UC60...

Page 9: ...T 9 C V D20 24 5 FC64 1 1085 48 0 31 2 15 00 21 60 2 1630 57 0 40 0 11 65 T 9X C16 21 0 FC64 1 1085 48 0 31 2 15 00 21 60 2 1550 57 0 40 0 11 85 T 9X C16 21 0 FC MC62D 1 1085 46 5 29 8 15 00 20 80 2...

Page 10: ...15 AHV36C 895 29 6 3 88 2 24 19 1 2 72 2 06 9 00 640 28 8 3 68 2 29 18 8 2 54 2 17 9 00 AV 36 960 29 4 4 02 2 14 18 9 2 80 1 98 9 00 725 28 9 3 75 2 26 18 9 2 80 1 98 9 00 MV12B FC MC43B 1000 29 6 3 8...

Page 11: ...4 12 2 84 25 4 2 70 2 76 8 98 MX16C FC60C 1150 40 5 4 12 2 88 25 4 2 82 2 64 9 00 995 40 0 3 90 3 01 25 2 2 76 2 68 8 98 MX20D FC MC60D 1295 41 0 4 24 2 83 25 4 2 88 2 58 9 00 MX20D FC MC62D 1470 40 0...

Page 12: ...43 0 3 62 2 1795 58 0 38 5 9 00 3 80 2 1390 57 0 38 5 8 60 3 52 MX20D FC64 1 1390 44 0 3 72 2 1795 58 0 39 0 9 00 3 94 2 1390 57 0 39 0 8 60 3 62 1 Rated CFM same as for cooling 2 Heating MBH based on...

Page 13: ...5 1 89 15 0 2 62 1 68 8 50 T 8 L V B12 FC MC PC35B 785 24 0 3 80 1 85 15 1 2 52 1 76 8 50 515 23 8 3 55 1 94 15 1 2 52 1 76 8 50 T 8 L V B12 FC MC PC43B 790 24 0 3 92 1 79 15 0 2 64 1 66 9 00 515 23 8...

Page 14: ...23 8 3 80 1 84 15 0 2 54 1 73 8 50 C 8 L C C16 FC MC PC43C 770 24 0 3 92 1 79 14 9 2 64 1 65 9 00 645 23 8 3 67 1 88 14 9 2 64 1 65 9 00 C 8 L C C20 FC MC PC35C 755 23 8 3 78 1 84 15 0 2 52 1 74 8 50...

Page 15: ...8C 1195 36 0 3 90 2 72 23 4 2 74 2 50 9 00 1000 36 0 3 30 3 36 23 4 2 74 2 50 9 00 T 8 L V C20 FC MC PC48C 1150 36 0 3 92 2 71 23 4 2 76 2 48 9 00 1000 36 0 3 32 3 35 23 4 2 76 2 48 9 00 T 9 C V D20 F...

Page 16: ...3 15 23 0 2 92 2 31 9 00 T 9X D20 UC48D 1240 36 0 4 10 2 60 23 2 2 86 2 38 9 00 1000 36 0 3 50 3 24 23 2 2 86 2 38 9 00 T 9X D20 UC60D 1310 36 0 4 22 2 53 23 0 2 88 2 34 9 00 1000 36 0 3 62 3 17 23 0...

Page 17: ...0 40 0 3 84 3 05 25 4 2 74 2 72 8 48 T 9 C V D20 FC MC PC60D 1225 41 0 4 06 2 96 25 8 2 78 2 72 8 50 1075 40 0 3 94 2 97 25 4 2 76 2 70 8 98 T 9 C V D20 FC MC62D 1455 41 0 4 08 2 94 25 8 2 74 2 76 8 2...

Page 18: ...0 48 0 3 37 4 33 34 4 2 72 3 71 9 00 T 8 L V C20 FC64 1630 48 0 3 88 3 85 34 2 2 74 3 66 9 00 1000 48 0 3 39 4 31 34 2 2 74 3 66 9 00 T 8 L X C16 FC64 1610 48 0 3 90 3 83 34 2 2 76 3 63 9 00 1000 48 0...

Page 19: ...30 T 8 L X C20 FC64 1 835 41 0 3 16 2 1665 58 0 38 5 9 00 3 84 2 835 56 5 39 0 8 75 2 92 T 9 C V C16 FC MC62D 1 1040 42 0 3 36 2 1590 58 0 38 5 9 00 3 64 2 1040 57 5 38 5 9 00 3 20 T 9 C V C16 FC64 1...

Page 20: ...58 0 38 5 9 00 3 78 2 1060 58 0 39 0 9 00 3 30 C 9C C16 FC MC62D 1 1040 42 0 3 36 2 1590 58 0 38 5 9 00 3 64 2 1040 57 5 38 5 9 00 3 20 C 9C C16 FC64 1 1040 42 5 3 46 2 1590 58 0 38 5 9 00 3 74 2 104...

Page 21: ...or units are fully compatiable with the Residential Touch Screen Communicating Control S1 TTSCC01 SOUND POWER LEVEL TYPICAL OCTAVE BAND SPECTRUM without tone adjustment Rated in accordance with ARI St...

Page 22: ...1 55 1 61 1 61 1 61 1 62 1 63 1 69 1 69 1 69 1 70 1 71 95 T C 20 0 21 1 21 0 23 0 24 8 21 5 21 9 21 8 23 8 25 7 23 1 22 6 22 5 24 5 26 7 S C 20 0 19 2 16 4 16 3 13 4 21 5 21 3 18 3 18 1 14 4 23 1 22 6...

Page 23: ...C V C16 FC MC PC43C 1 01 0 99 0 99 T 9 C V C20 FC MC PC35C 0 99 0 96 0 97 T 9 C V C20 FC MC PC43C 1 02 1 05 0 99 T 9V A10 FC MC PC32A 0 98 0 96 1 03 T 9V A10 FC MC PC37A 0 99 0 98 1 03 T 9X A10 FC MC...

Page 24: ...29 7 26 2 25 9 25 3 27 7 30 5 S C 23 2 23 0 19 4 19 2 15 3 24 7 24 8 21 5 21 2 16 4 26 2 25 9 23 5 23 1 17 6 K W 2 27 2 27 2 27 2 27 2 28 2 35 2 34 2 34 2 34 2 35 2 42 2 42 2 42 2 42 2 42 115 T C 22...

Page 25: ...56 2 56 2 57 2 60 2 65 2 64 2 65 2 65 2 69 95 T C 30 6 31 5 31 6 34 6 37 6 32 1 32 3 32 3 35 2 38 4 33 7 33 0 33 0 35 8 39 2 S C 30 6 29 1 24 6 24 3 19 6 32 1 31 1 26 6 26 2 20 6 33 7 33 0 28 7 28 2 2...

Page 26: ...9 C V D20 FC MC PC48D 0 99 0 99 0 94 T 9 C V D20 FC MC PC60D 1 00 1 00 0 94 T 9X C16 FC MC PC48C 1 01 1 03 0 95 T 9X C16 FC PC60C 1 01 1 05 0 94 T 9X C16 UC48C 1 01 1 03 0 95 T 9X C16 UC60C 0 99 1 04...

Page 27: ...3 2 82 2 90 2 92 2 92 2 89 2 90 2 97 3 00 3 00 2 95 2 98 95 T C 35 1 35 9 35 9 39 6 43 3 36 7 36 5 36 6 40 2 44 0 38 2 37 1 37 3 40 8 44 6 S C 33 4 32 3 27 1 26 8 21 1 34 9 33 8 29 1 28 7 22 1 36 3 35...

Page 28: ...D20 FC MC PC60D 0 98 0 99 1 00 T 9 C V D20 FC MC62D 1 00 1 03 1 05 T 9 C V D20 UC60D 0 97 0 97 1 00 T 9X C16 FC MC62D 1 00 1 04 1 03 T 9X C16 FC PC60C 1 01 1 03 1 01 T 9X C16 UC60C 0 98 1 01 1 00 T 9...

Page 29: ...6 33 4 33 0 26 3 42 4 42 0 35 3 34 9 27 4 43 9 43 4 37 3 36 7 28 4 K W 3 56 3 56 3 56 3 59 3 62 3 64 3 64 3 64 3 67 3 70 3 73 3 72 3 72 3 75 3 79 105 T C 38 2 38 6 38 6 42 6 46 5 39 6 39 6 39 2 43 1 4...

Page 30: ...29 1 48 0 47 2 39 8 39 1 30 1 49 3 49 0 41 6 40 9 31 1 K W 5 22 5 23 5 23 5 32 5 41 5 32 5 33 5 32 5 41 5 50 5 43 5 42 5 41 5 50 5 59 115 T C 43 6 43 3 43 2 47 5 51 7 44 7 44 6 43 8 48 0 52 2 45 9 45...

Page 31: ...2 0 88 MX12B FC MC35B 0 97 1 12 0 87 MX12B FC MC43B 0 97 1 10 0 87 Furnace Coil MBH COP KW T 8 L V A12 FC MC PC32A 0 97 1 07 0 91 T 8 L V A12 FC MC PC37A 0 98 1 12 0 88 T 8 L V B12 FC MC PC35B 0 97 1...

Page 32: ...02 15 0 2 16 2 04 70 16 6 2 21 2 20 16 4 2 17 2 21 16 1 2 14 2 21 80 16 4 2 01 2 39 16 8 2 06 2 40 17 3 2 12 2 38 NOTE ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED KW VALUES ARE FOR T...

Page 33: ...1 00 1 01 0 99 AHV42D 0 98 1 06 0 92 AHV48D 0 97 1 06 0 92 AV 48 0 98 1 12 0 88 MV12D FC MC48D 0 98 1 08 0 91 MV12D FC MC60D 0 98 1 09 0 90 MV16C FC MC48C 0 98 1 06 0 93 MX12D FC MC48D 0 98 1 06 0 93...

Page 34: ...V16C FC60C 1 00 1 10 0 91 MV20D FC MC60D 1 00 1 12 0 89 MV20D FC MC62D 0 99 1 11 0 89 MX16C FC60C 0 99 1 11 0 89 MX20D FC MC60D 1 00 1 15 0 87 MX20D FC MC62D 0 98 1 15 0 85 Furnace Coil MBH COP KW T 8...

Page 35: ...39 1 2 67 4 29 17 60 34 0 2 79 3 57 34 2 2 84 3 53 34 5 2 89 3 50 70 33 2 2 46 3 96 33 5 2 51 3 91 33 8 2 57 3 85 80 32 5 2 20 4 32 32 7 2 25 4 26 33 0 2 30 4 20 10 60 29 5 2 56 3 38 29 7 2 57 3 38 2...

Page 36: ...4 17 35 2 2 48 4 16 35 4 2 50 4 15 70 34 7 2 23 4 57 34 9 2 25 4 55 35 1 2 28 4 51 80 34 4 2 03 4 97 34 6 2 06 4 93 34 8 2 09 4 89 NOTE ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED KW...

Reviews: