Specifications
4.2.5 I/O Module Cable
The I/O Module cable (Table 4-8) is included with the 1350 I/O Breakout Module, optional 1460
I/O Expansion Module and the optional 1450 I/O Expansion Module. The I/O Module cable
connects the In-Sight 3400 sensor directly to the applicable I/O Expansion module via the DB15
connector. When the 1350 Breakout Module, 1460 I/O Expansion Module or 1450 I/O Expansion
Module is used, all power and communication lines used by the In-Sight 3400 sensor are
connected via the I/O Module cable.
The I/O Module cable is available in 5M (PN 185-0099) and 10M (PN 185-0090) lengths.
NOTE
Refer to the 1460 I/O Expansion Module, 1450 I/O Expansion Module or 1350 Breakout
Module Installation Manual for more connection information.
Table 4-8: I/O Module Cable Pin-Out
P1 PIN#
SIGNAL NAME
P2 PIN#
1
Power, +24 VDC
1
2 Trigger
+
2
3 Trigger
-
3
4
High-Speed Out 0
4
5
High-Speed Out 1
5
6
RS-232 Receive (RxD)
6
7
RS-232 Transmit (TxD)
7
8 Ground
8
46