Installing the In-Sight
®
3400 Vision Senso
r
4.2.4 24VDC Breakout Connector and Cable Specifications
The 24VDC Breakout connector provides access to power, serial communications, trigger and
high-speed outputs. The Breakout cable is not terminated (Table 4-7).
Table 4-7: 24VDC Breakout Connector Cable Pin-Out
PIN#
SIGNAL NAME
WIRE COLOR
1
Power, +24 VDC
White/Green
2 Trigger
+
Green
3 Trigger
-
White/Orange
4
High-Speed Out 0
Blue
5
High-Speed Out 1
White/Blue
6
RS-232 Receive (RxD) *
Orange
7
RS-232 Transmit (TxD) *
White/Brown
8 Ground
Brown
* If hardware handshaking is required, an I/O Expansion Module must be used.