In-Sight 3400 Installation
Table 2-1: In-Sight 3400 Vision Sensor Connections and Indicators
CONNECTOR/
INDICATOR
FUNCTION
CONTROL
PAD Connector
Connects the In-Sight Control Pad, which is used to navigate the spreadsheet user
interface. The Control Pad is not required when the In-Sight 3400 sensor is
accessed remotely from a PC running In-Sight software.
PWR LED
This PWR LED indicates the power status of the In-Sight 3400 sensor. The LED is
red when the sensor is receiving power during initialization, momentarily switches
from green to orange during the LED start-up test, and then switches back to green
after initialization is completed. If initialization fails, the LED remains red. The LED
blinks red if the power supply is overloaded, causing the power to cycle. If the
sensor is rebooting, the PWR LED is orange.
ENET LED
The ENET LED is orange during the LED start-up test, momentarily switches to
green when a network connection is established, and then blinks green and orange
when network traffic is detected. If a network connection cannot be established, the
LED is not lit.
24VDC
Connector
Connects the In-Sight Breakout Cable, which provides connections to an external
power supply, the acquisition trigger input, high-speed outputs and RS-232 serial
communications. Alternatively, this connector is used to attach the I/O Cable to an
optional In-Sight I/O Expansion Module, which adds general-purpose discrete I/O
and light control functionality. Refer to Table 4-7 and Table 4-8, pages 45 and 46.
ENET
Connector
Connects the In-Sight sensor to a network. The ENET connector provides the
Ethernet connection to external network devices. Refer to Table 4-9, page 47.
CAM
Connector
The CAM connector attaches the remote head camera to the In-Sight 3400 sensor.
Refer to Table 4-10, page 48.
CAM LED
The CAM LED indicates the status of the remote head camera. The LED is orange
during the LED start-up test and then switches to green when the camera is
connected to the sensor and the synchronization signal is established. The LED is
orange when the camera is acquiring an image and blinks red if the camera loses
sync. If the camera does not sync-lock during initialization, the LED is solid red.
HSOUT 0/1
LEDs
These LEDs indicate the status of the two High-Speed outputs. The applicable LED
is green when active.
USER 0/1
LEDs
The User 0 LED lights green; User 1 lights red when triggered by a user-definable
event. Refer to the “WriteDiscrete” topic in the
In-Sight
®
Explorer Help
file for
information on configuring the behavior of User 0/1 LEDs.
VGA
Connector
Connects a standard VGA or flat panel display. A display is not needed when
configuring or monitoring an In-Sight 3400 sensor from a remote PC location.
Refer to Table 4-11, page 49.
8
Summary of Contents for In-Sight 3400
Page 1: ......
Page 2: ......
Page 6: ...Precautions iv ...
Page 12: ...List of Tables x ...
Page 46: ...In Sight 3400 Installation 34 ...
Page 88: ...Installing the Remote Head Camera Mount 76 ...
Page 90: ...Installing the In Sight 3400 Vision Sensor www cognex com P N 597 0025 02 ...