In-Sight 3400 Installation
2.2 Connecting the Model 1350 Breakout Module
The optional In-Sight Breakout Module (P/N 800-5743) is a convenient way to connect the
In-Sight 3400 sensor’s power, serial communications, and I/O lines.
To In-Sight
System
To Serial
Device
2-Pin Power
Adapter Plug
Trigger Input,
Discrete Outputs,
24VDC
(16-pin Terminal
Block)
Figure 2-5: Breakout Module Connections
To Connect the Model 1350 Breakout Module to the In-Sight 3400
Sensor:
1. Verify the 24VDC power supply being used is switched off.
2. Optionally, connect the power and ground wires for the acquisition trigger input and the
discrete outputs to their corresponding terminals on the Breakout Module.
3. Optionally, connect the DB9 male connector of an RS-232 serial cable to the corresponding
DB9 female connector on the Breakout Module.
4. Plug the DB15 male connector of the Breakout Module cable into the corresponding female
connector on the Breakout Module.
5. Plug the M12 connector of the Breakout Module cable into the In-Sight 3400 sensor’s
24VDC connector.
6. Plug the wire leads from a 24VDC supply for the +24V power and ground into the 2-pin
terminal plug on the Breakout Module. Alternatively, remove the terminal plug and insert the
2-pin terminal plug attached to the In-Sight power adapter into the keyed power adapter port
on the Breakout Module (Figure 2-5).
7. Restore power to the 24V supply. The green PWR LED on the In-Sight 3400 sensor and the
24V LED on the Breakout Module will indicate that the In-Sight 3400 sensor and
Breakout Module are receiving power.
12