0. DESCRIPTION.
ONEMATIC easy
is a compact automatic control unit for single-phase elctric pumps. The system manages the start and stop of the
pump depending on the pressure detected by its internal transducer and the flow detected by the internal flow sensor. It can be run
either in
pressure-dependent mode
(start pressure and stop pressure) or
on/off mode
(start pressure between 1÷5 bar, stopped by
the flow sensor).
1. CLASSIFICATION AND TYPE.
According to EN-60730-1
ONEMATIC easy
is a unit of independent assembly, type 1B with software of class A, for floodproof
installation in clean or slightly contaminated environments.
2.
MAIN CHARACTERISTICS.
n
Pump controlled by power relay.
n
2 operating modes:
pressure-dependent
or
on/off
mode.
n
Control and protection system against over-current.
n
Control and protection system against dry running.
n
ART
function (Automatic Reset Test). When the unit is stopped due to a lack of water, the
ART
system attempts to re-start the unit in
programmed intervals.
n
Automatic restore of system after interruption of power supply. System restores the previous mode.
n
Volt-free contact for monitoring the alerts displayed in screen, which were caused by irregularities or problems within the system
(OPTIONAL on request).
n
Input for monitoring the minimum water level in inlet tank. This function is independent of the protective system against dry running and
optional (OPTIONAL on request).
n
Internal pressure transducer.
n
Internal flow sensor.
n
Control panel:
n
LCD screen, for configuration menu and indication of alerts with permanent pressure indication.
n
START/STOP push-button to operate the pump manually.
n
AUTOMATIC push-button with mode LED .
n
Keyboard for accessing the configuration menu.
n
Digital gauge.
3. CONTROL PANEL.
1.
-
LCD screen
: during the configuration process, it shows the different parameters. When
ONEMATIC easy
is running, it shows the
current pressure, the configured target pressure and the alerts.
2.
- Push-button
PUMP Start-Stop:
will only run with the automatic mode disabled (
AUTO
LED off).
3.
- Push-button
AUTO On/Off:
for choosing between manual and automatic operating modes.
4.-
Push-button
MENU:
for accesing or exiting the configuration menu.
5.-
Push-button
ENTER:
used for saving configured values. Each time the button is pushed, a new field opens in the configuration
menu. Press MENU if you wish to exit the configuration sequence.
6.-
Push-buttons
p
and
q
: to increase or decrease the configuration parameters.
7.-
LINE
LED
(green): lit when the unit is connected to the electric supply.
8.-
FAILURE
LED
(red): lit or flashing depending on type of failure.
9.-
AUTO
LED
(green): lit in automatic mode and off in manual operating mode.
10.-
PUMP
LED
(yellow): lit when the pump is running.
E