9711IMA-70
Maintenance
15-1
15.
Maintenance
This section describes the maintenance procedures for this antenna system. Also refer to the Troubleshooting section of
this manual for troubleshooting details.
WARNING: Electrical Hazard – Dangerous AC Voltages exist in the Breaker Box and the
Antenna Pedestal Power Supply. Observe proper safety precautions when working inside the
Antenna Breaker Box or Power Supply.
WARNING: RF Radiation Hazard - This stabilized antenna system is designed to be used with
transmit/receive equipment manufactured by others. Refer to the documentation supplied by
the manufacturer which will describe potential hazards, including exposure to RF radiation,
associated with the improper use of the transmit/receive equipment. Note that the
transmit/receive equipment will operate independently of the stabilized antenna system.
The ultimate responsibility for safety rests with the facility operator and the
individuals who work on the system.
WARNING: RF Radiation Hazard - Prior to working on the stabilized antenna system, the power
to the
transmit/receive equipment must be locked out and tagged. Turning OFF power to
the Antenna Control Unit does NOT turn Transmit power output OFF.
The ultimate responsibility for safety rests with the facility operator and the
individuals who work on the system.
WARNING: RF Radiation Hazard - When the transmit/receive system is in operation, no one
should be allowed anywhere within the radiated beam being emitted from the reflector.
The ultimate responsibility for safety rests with the facility operator and the
individuals who work on the system.
15.1.
Warranty Information
Sea Tel Inc. supports these systems with a TWO year warranty on parts and labor.
What’s Covered by the Limited Warranty?
The Sea Tel Limited Warranty is applicable for parts and labor coverage to the complete antenna system, including
all ADE (radome, pedestal, antenna, motors, electronics, wiring, etc.) and the ACU or MXP.
What’s
NOT
Covered by the Limited Warranty?
It does
not
include Transmit & Receive RF Equipment, Modems, Multiplexers or other distribution equipment,
whether or not supplied by Sea Tel commonly used in Satellite Communications (TXRX) Systems. These
equipments are covered by the applicable warranties of the respective manufacturers.
Original installation of the system must be accomplished by, or under the supervision of, an authorized Sea Tel
dealer for the Sea Tel Limited Warranty to be valid and in force.
Should technical assistance be required to repair your system, the first contact should be to the agent/dealer you
purchased the equipment from.
Please refer to the complete warranty information included with your system.
15.2.
Torque and Loctite Specifications
WARNING: Assure that all nut and bolt assemblies are tightened according to the
tightening torque values listed below:
SAE Bolt Size
Inch Pounds
Metric Bolt Size
Kg-cm
1/4-20
75
M6
75.3
5/l6-18
132
M8
150
3/8-16
236
M10
270
1/2-13
517
M12
430
EAR Controlled - ECCN EAR99
Summary of Contents for SEA TEL 9711IMA-70
Page 6: ...9711IMA 70 vi This Page Intentionally Left Blank EAR Controlled ECCN EAR99...
Page 10: ...9711IMA 70 Table of Contents x This Page Intentionally Left Blank EAR Controlled ECCN EAR99...
Page 14: ...Introduction 9711IMA 70 1 4 This Page Intentionally Left Blank EAR Controlled ECCN EAR99...
Page 60: ...Setup Azimuth Trim 9711IMA 70 7 2 This Page Intentionally Left Blank EAR Controlled ECCN EAR99...
Page 74: ...Setup Targeting 9711IMA 70 10 4 This Page Intentionally Left Blank EAR Controlled ECCN EAR99...
Page 124: ...Drawings 9711IMA 70 18 2 This Page Intentionally Left Blank EAR Controlled ECCN EAR99...
Page 132: ...EAR Controlled ECCN EAR99...
Page 133: ...EAR Controlled ECCN EAR99...
Page 134: ...EAR Controlled ECCN EAR99...
Page 159: ...EAR Controlled ECCN EAR99...
Page 160: ...EAR Controlled ECCN EAR99...
Page 165: ...EAR Controlled ECCN EAR99...
Page 177: ...EAR Controlled ECCN EAR99...
Page 178: ...EAR Controlled ECCN EAR99...