Compass Safe Distance:
SAILOR 900 Ka antenna or ADU (Above Deck Unit): min. 100 cm (ENC 60945).
SAILOR 900 Ka ACU (Antenna Control Unit): min. 10 cm (EN 60945)
Service
User access to the interior of the ACU is not allowed. Only a technician authorized by Cobham
SATCOM may perform service - failure to comply with this rule will void the warranty.
Access to
the interior of the Above Deck Unit is allowed. Replacement of certain modules and general
service may only be performed by a technician authorized by Cobham SATCOM.
Grounding, cables and connections
To minimize shock hazard and to protect against lightning, you must connect the equipment
chassis and cabinet to an electrical ground. Ground the ACU to the ship. For further details see
Appendix B,
.
Do not extend the cables beyond the lengths specified for the equipment. The cable between
the ACU and Above Deck Unit can be extended if it complies with the specified data
concerning cable losses etc.
Rx and Tx cables for the SAILOR 900 Ka system are shielded and should not be affected by
magnetic fields. However, try to avoid running cables parallel to high power and AC/RF wiring as
this might cause malfunction of the equipment.
Power supply
The voltage range for the SAILOR 900 Ka ADU and ACU is 20 – 32 VDC. The Above Deck Unit is
powered by the ACU.
If a DC power bus is not available, an external 115/230 VAC to 28 VDC power supply can be
used, for example a SAILOR 6080 Power Supply.
Do not operate in an explosive atmosphere
Do not operate the equipment in the presence of flammable gases or fumes. Operation of any
electrical equipment in such an environment constitutes a definite safety hazard.
Keep away from live circuits
Operating personnel must not remove equipment covers. Component replacement and internal
adjustment must be made by qualified maintenance personnel. Do not replace components
with the power cable connected. Under certain conditions, dangerous voltages may exist even
with the power cable removed. To avoid injuries, always disconnect power and discharge
circuits before touching them.
Failure to comply with the rules above will void the warranty!
SAILOR900Ka-IM-98-146706.book Page iv Thursday, July 16, 2015 11:07 AM