Software update
98-146706-A
Chapter 8: Service
8-5
Service
8.2
Software update
8.2.1
Prerequisites
The following items are required to make a software update:
• One computer with a standard Ethernet port available.
• A standard Internet browser.
• 1024×768 pixels or higher display resolution (best viewed with small fonts).
• One straight LAN cable.
• Access to the file with the new software.
8.2.2
Software update (ADU, ACU)
The upload procedure takes a couple of minutes. When done, the ACU automatically
restarts with the new software version. The start-up procedure after a software upload
takes longer than the usual start-up time, as the software in the ADU must also be updated.
This is shown in the ACU display as
ADU SW UPLOAD
.
To make a software update, do as follows:
1. Power up the SAILOR 900 Ka system, i.e. switch on the ACU. Wait until the SAILOR logo
has disappeared from the ACU display.
2. Connect a PC to LAN interface 3 (Service port, standard Ethernet) of the ACU or to the
front LAN connector of the ACU.
If you want to use another LAN port to access the web interface you must configure it
according to your network requirements. See
24 for more information.
3. Open your Internet browser and enter the IP address of the ACU. The default IP address
is http://192.168.0.1.
4. Type in the user name
admin
and the password
1234
to access the
Dashboard
.
5. The web interface shows the
DASHBOARD
page.
6. Click
SERVICE
in the navigation pane. The
UPLOAD SOFTWARE TO TERMINAL
page is displayed.
Note
Software update should only be done by qualified service personnel.
Figure 8-2: LAN 3 connector used for configuring the SAILOR 900 Ka
SAILOR900Ka-IM-98-146706.book Page 5 Thursday, July 16, 2015 11:07 AM