Power up
98-146706-A
Chapter 5: Power and startup
5-3
Po
w
er and star
tup
Examples for using the
SAILOR 6080 AC/DC Power Supply
:
AWG11
max
=0.5 x (60 mOhm-0)/4.8 mOhm/m = 6.2 m
AWG10
max
=0.5 x (60 mOhm-0)/3.8 mOhm/m = 7.9 m
5.3
Power up
5.3.1
To connect the power cable to the ACU
1. Connect the positive and negative input terminals to the ship's DC supply according to
2. Connect the power plug to DC Input.
3. Connect the power cable to the modem.
5.3.2
Power-up procedure
1. Connect power to the modem.
2. Switch on the ACU. The unit starts up and goes through an initialization procedure:
• ACU POST
• ADU Initializing
• ADU POST
• READY
This may take some time (up to a couple of minutes).
3. The SAILOR 900 Ka is ready to be calibrated (for first time power up) or receive data
from the modem (when in normal operation).
The LEDs
Power
and
Fail/Pass
are
steady green
, the LED Logon is off. For further
information on status indicators see
Status signalling with LEDs and status messages
on page 8-8.
Make sure there are no hardware failures or error codes present, check the display of the
ACU for events. For more information on error codes and events see
4. Make an azimuth and a cable loss calibration, see
5. Create one or more VSAT modem profiles. See
6. Create one or more satellite profiles. See
Figure 5-2: ACU - to connect power to DC Input