HCS-D User Manual
28
Figure 8: Preferred Orientation
of the NEMA Receptacles Below
the Plug-in HCS-D
RECEPTACLE INSTRUCTIONS
(Plug-In HCS-D)
The plug-in HCS-D is fitted with either a NEMA 14-50 or
6-50 plug extending from the bottom of the HCS-D enclosure.
Regulations limit this plug to a maximum of 12 inches in length,
including the plug head. For this reason, the plug-in HCS-D must
be mounted above the NEMA receptacle and must also be located
within 12 inches of it.
In both NEMA 14-50P and
6-50P configurations, the
ground pin is located at the
furthest point on the plug.
It is recommended that a
NEMA 14-50R or 6-50R
receptacle be oriented
accordingly, such that the
ground socket is at the
lowest point.
12
”
Maximum
NEMA
14-50R
NEMA
6-50R
Ground
Ground