Page 34
ODF Speed Facer Operating Manual
NOTICE
Jacking leveling and standard jaws only have 1.7"
(43 mm) of travel.
6. Rig the machine onto the flange by placing the
setup fingers against the bolting flange surface.
7. Tighten the leveling feet screws equally until
the jaws are against the flange OD with 10 ft-lbs
(14 Nm) of torque.
3.4.1
Chuck feet extensions
The ODF Speed Facer has chuck feet extensions that
expand the OD range as shown in Table 3-11.
3.4.2
Chuck foot spacers
Each chuck foot spacer provides 1.97" (50 mm) of clear-
ance off the face of the workpiece. Up to two chuck
foot spacers may be used on each mounting foot. These
are normally used when the chucking diameter eleva-
tion is more than 1" (25 mm) below the elevation of the
surface being machined.
Do the following to install the chuck foot spacers:
1. Securely position the machine to allow access
to the mounting feet.
2. Remove the mounting foot noting the frame
hole location being used.
3. Remove existing fasteners noting the mounting
holes being used.
4. Install the supplied fasteners in the mounting
foot using the same mounting holes.
5. Stack either one or two chuck foot spacers on
top of the mounting foot and over the fasten-
ers.
6. Reinstall the mounting foot to the machine
using the same frame hole location.
7. Repeat for all mounting feet.
F
IGURE
3-7. C
HUCK
FOOT
SPACERS
3.4.3
Centering and leveling
Do the following to center and level the machine:
1. For coarse adjustment, check the distance
between the inner diameter (ID) of the machine
and the OD of the pipe with a tape measure at
the four leveling feet.
2. For fine adjustment, use a dial indicator in the
tool holder to check the same measurements
between the ID of the machine and the OD of
the pipe. Adjustment in both cases is made with
the jacking foot screws.
3. As the setup fingers achieve the initial leveling,
do the following to fine tune the level:
a) Mount a dial indicator in the tool holder
centered over the raised flange surface.
b) Zero out the indicator over the first level-
ing foot and rotate the machine 180° to
position the indicator in-line with the
opposing foot.
T
ABLE
3-11. S
PEED
F
ACER
OD
RANGES
Machine
Outer diameter
range
OD range with
optional extended
mounting feet
ODF30 Speed Facer
19.1 - 30.5"
(489 - 779 mm)
9.1 - 20.0"
(235 - 266 mm)
ODF40 Speed Facer
29.1 – 40.5"
(739 – 1,029 mm)
19.1 – 30.0"
(485 – 762 mm)
ODF50 Speed Facer
39.1 – 50.5"
(993 – 1,283 mm)
29.1 – 40.0"
(739 – 1016 mm)
ODF60 Speed Facer
49.1 – 60.5"
(1,247 – 1,537 mm)
39.1 – 50.0"
(993 – 1,270 mm)
ODF70 Speed Facer
59.1 – 70.5"
(1,501 – 1,791 mm)
49.1 – 60.0"
(1,247 – 1,524 mm)
ODF80 Speed Facer
69.1 - 80.5"
(1,755 – 2,045 mm)
59.1 – 70.0"
(1,501 – 1,778 mm)
ODF90 Speed Facer
79.2 – 90.5"
(2,011 - 2,298 mm)
69.2 - 90.5"
(1,757 - 2,298 mm)
ODF100 Speed Facer
89.2 – 100.5"
(2,265 – 2,552 mm)
79.2 - 100.5 in
(2011 - 2552 mm
ODF110 Speed Facer
99.1 - 110.5"
(2,517 - 2,817 mm)
89.1 - 100"
(2,263 - 2,540 mm)
ODF120 Speed Facer
109.1 - 120.5"
(2,771 - 3,061 mm)
99.1 - 110"
(2,517 - 2,794 mm)
Summary of Contents for H&S TOOL SPEED FACER ODF100
Page 2: ......
Page 4: ...Page B ODF Speed Facer Operating Manual CLIMAX GLOBAL LOCATIONS ...
Page 5: ...P N 102615 Rev 0 Page C CE DOCUMENTATION ...
Page 6: ...Page D ODF Speed Facer Operating Manual CE DOCUMENTATION ...
Page 8: ...Page F ODF Speed Facer Operating Manual This page intentionally left blank ...
Page 11: ...P N 102615 Rev 0 Page iii TABLE OF CONTENTS CONTINUED CHAPTER SECTION PAGE APPENDIX B SDS 111 ...
Page 12: ...Page iv ODF Speed Facer Operating Manual This page intentionally left blank ...
Page 16: ...Page viii ODF Speed Facer Operating Manual This page intentionally left blank ...
Page 18: ...Page viii ODF Speed Facer Operating Manual This page intentionally left blank ...
Page 62: ...Page 44 ODF Speed Facer Operating Manual This page intentionally left blank ...
Page 106: ...Page 88 ODF Speed Facer Operating Manual FIGURE A 28 ODF120 SPEED FACER ASSEMBLY P N 7639 S1 ...
Page 107: ...P N 102615 Rev 0 Page 89 FIGURE A 29 ODF120 SPEED FACER LABEL LOCATIONS P N 89210 ...
Page 123: ...P N 102615 Rev 0 Page 105 FIGURE A 45 HYDRAULIC DRIVE MOTOR ASSEMBLY P N 91110 ...
Page 126: ...Page 108 ODF Speed Facer Operating Manual FIGURE A 48 CABLE PROTECTION COMPONENTS ...
Page 128: ...Page 110 ODF Speed Facer Operating Manual This page intentionally left blank ...
Page 130: ...Page 112 ODF Speed Facer Operating Manual This page intentionally left blank ...
Page 131: ......
Page 132: ......