13
EN
TECHNICAL SPECIFICATIONS
i-CXW 2-pipe system
1 Room temperature 27°C d.b. / 18.9°C w.b.; Chilled water (in/out) 7°C/12°C.
2 Room temperature 20°C d.b.; Hot water (in/out) 45°C/40°C.
3 Sound pressure level in an essentially free field on a reflecting floor, 1 m in front of the fans and 1 m above the floor.
Non-binding value obtained from the sound power level.
4 Sound power based on measurements performed in accordance with ISO 3741 and Eurovent 8/2.
5 Unit in standard configuration and construction, without optional accessories.
6 Values refer to EN 14511
7 Values refer to [REGULATION (EU) No. 2016/2281]
Certified data in EUROVENT
i-CXW
502
602
702
802
1102
ELECTRICAL DATA
Power supply
V/ph/Hz
230/1/50 230/1/50 230/1/50 230/1/50 230/1/50
2 PIPES SYSTEM CONFIGURATION
ENERGY EFFICIENCY
COOLING (EN14511 VALUE)
FCEER
(1)(6)
kW/kW
307
319
219
346
292
FCEER Class
A
A
A
A
A
HEATING ONLY (EN14511 VALUE)
FCCOP
(2)(6)
kW/kW
316
314
222
360
284
FCCOP Class
A
A
B
A
A
PERFORMANCE
MIN SPEED
Fan Power Input
-1
W
5,37
5,72
6,57
9,96
10,7
Air flow rate
-1
m³/h
310
310
360
630
710
Total capacity in cooling mode
-1
kW
1,84
2,24
2,55
4,2
5,28
Total Net Cooling Capacity
(1)(6)(7)
kW
1,84
2,24
2,54
4,19
5,27
Sensible capacity in cooling mode
-1
kW
1,35
1,57
1,8
3,03
3,69
Net sensible cooling capacity
(1)(6)(7)
kW
1,34
1,56
1,79
3,02
3,68
Net latent power in cooling
(1)(6)(7)
kW
0,49
0,67
0,75
1,17
1,59
Max water flow
-1
m³/h
0,09
0,11
0,12
0,2
0,25
Pressure Drop in cooling mode
-1
kPa
4,8
4,5
5,7
10,5
9
Total capacity (heating mode)
-2
kW
1,85
2,12
2,46
4,26
4,89
Total Net Heating Capacity
(2)(6)
kW
1,86
2,13
2,47
4,27
4,9
Water flow in heating mode
-2
m³/h
0,09
0,1
0,12
0,21
0,24
Pressure drop in heating mode
-2
kPa
4,4
3,7
4,8
9,8
7,1
Sound Pressure
-3
dB(A)
24
24
28
24
25
Sound Power
(4)(7)
dB(A)
33
33
37
33
34
MED SPEED
Fan Power Input
-1
W
7,54
10,3
21,9
17,2
31,3
Air flow rate
-1
m³/h
380
445
610
870
1130
Total capacity in cooling mode
-1
kW
2,16
3,05
3,87
5,14
7,71
Total Net Cooling Capacity
(1)(6)(7)
kW
2,15
3,04
3,85
5,13
7,68
Sensible capacity in cooling mode
-1
kW
1,61
2,17
2,81
3,76
5,53
Net sensible cooling capacity
(1)(6)(7)
kW
1,6
2,16
2,79
3,74
5,5
Net latent power in cooling
(1)(6)(7)
kW
0,55
0,88
1,06
1,38
2,18
Max water flow
-1
m³/h
0,1
0,15
0,19
0,25
0,37
Pressure Drop in cooling mode
-1
kPa
6,4
7,9
12,1
15,2
17,9
Total capacity (heating mode)
-2
kW
2,21
2,97
3,83
5,29
7,31
Total Net Heating Capacity
(2)(6)
kW
2,22
2,98
3,85
5,31
7,34
Water flow in heating mode
-2
m³/h
0,11
0,14
0,18
0,26
0,35
Pressure drop in heating mode
-2
kPa
5,9
6,7
10,5
14,2
14,4
Sound Pressure
-3
dB(A)
30
34
41
30
38
Sound Power
(4)(7)
dB(A)
39
43
50
39
47
MAX SPEED
Fan Power Input
-1
W
16,1
31,1
61,7
33
108
Air flow rate
-1
m³/h
535
710
880
1165
1770
Total capacity in cooling mode
-1
kW
2,74
4,33
5,02
6,33
10,8
Total Net Cooling Capacity
(1)(6)(7)
kW
2,73
4,3
4,96
6,3
10,7
Sensible capacity in cooling mode
-1
kW
2,09
3,18
3,74
4,72
7,94
Net sensible cooling capacity
(1)(6)(7)
kW
2,07
3,15
3,68
4,69
7,83
Net latent power in cooling
(1)(6)(7)
kW
0,65
1,15
1,28
1,61
2,87
Max water flow
-1
m³/h
0,13
0,21
0,24
0,3
0,52
Pressure Drop in cooling mode
-1
kPa
9,9
14,9
19,4
22,2
33
Total capacity (heating mode)
-2
kW
2,85
4,33
5,09
6,67
10,5
Total Net Heating Capacity
(2)(6)
kW
2,87
4,36
5,15
6,7
10,6
Water flow in heating mode
-2
m³/h
0,14
0,21
0,25
0,32
0,51
Pressure drop in heating mode
-2
kPa
9,2
12,9
17,3
21,3
27,2
Sound Pressure
-3
dB(A)
38
45
51
39
48
Sound Power
(4)(7)
dB(A)
47
54
60
48
57
SIZE AND WEIGHT
A
-5
mm
575
575
575
820
820
B
-5
mm
575
575
575
820
820
H
-5
mm
275
275
275
303
303
Operating weight
-5
kg
22
24
24
36
39