TECHNICAL SPECIFICATIONS
a-CXW 2-pipe system
1 Room temperature 27°C d.b. / 18.9°C w.b.; Chilled water (in/out) 7°C/12°C.
2 Room temperature 20°C d.b.; Hot water (in/out) 45°C/40°C.
3 Sound pressure level in an essentially free field on a reflecting floor, 1 m in front of the fans and 1 m above the floor.
Non-binding value obtained from the sound power level.
4 Sound power based on measurements performed in accordance with ISO 3741 and Eurovent 8/2.
5 Unit in standard configuration and construction, without optional accessories.
6 Values refer to EN 14511
7 Values refer to [REGULATION (EU) No. 2016/2281]
Certified data in EUROVENT
a-CXW
402
502
602
702
802
1102
1202
ELECTRICAL DATA
Power supply
V/ph/Hz 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50
2 PIPES SYSTEM CONFIGURATION
ENERGY EFFICIENCY
COOLING (EN14511 VALUE)
FCEER
(1)(6)
kW/kW
48
72
81
77
113
113
101
FCEER Class
E
D
C
D
C
C
C
HEATING ONLY (EN14511 VALUE)
FCCOP
(2)(6)
kW/kW
54
74
79
78
117
108
102
FCCOP Class
E
D
D
D
C
C
C
PERFORMANCE
MIN SPEED
Fan Power Input
-1
W
25
25
25
32
33
42
42
Air flow rate
-1
m³/h
310
310
320
430
630
710
710
Total capacity in cooling mode
-1
kW
1,51
1,85
1,85
2,36
4,14
4,52
4,52
Total Net Cooling Capacity
(1)(6)(7)
kW
1,25
1,82
2,23
2,91
4,18
5,27
5,27
Sensible capacity in cooling mode
-1
kW
1,01
1,35
1,58
2,08
3,03
3,46
3,71
Net sensible cooling capacity
(1)(6)(7)
kW
0,99
1,33
1,56
2,05
3
3,42
3,67
Net latent power in cooling
(1)(6)(7)
kW
0,26
0,49
0,67
0,86
1,18
1,86
1,6
Max water flow
-1
m³/h
0,06
0,09
0,11
0,14
0,2
0,25
0,25
Pressure Drop in cooling mode
-1
kPa
4,3
4,8
4,5
7,3
10,5
9,1
11,1
Total capacity (heating mode)
-2
kW
1,35
1,82
2,1
2,82
4,24
4,88
5,08
Total Net Heating Capacity
(2)(6)
kW
1,37
1,85
2,12
2,85
4,27
4,92
5,12
Water flow in heating mode
-2
m³/h
0,07
0,09
0,1
0,14
0,2
0,24
0,25
Pressure drop in heating mode
-2
kPa
4,9
4,2
3,6
6,1
9,7
7,1
7,6
Sound Pressure
-3
dB(A)
24
24
24
32
24
25
25
Sound Power
(4)(7)
dB(A)
33
33
33
41
33
34
34
MED SPEED
Fan Power Input
-1
W
32
32
44
57
48
63
95
Air flow rate
-1
m³/h
420
420
500
610
820
970
1280
Total capacity in cooling mode
-1
kW
1,63
2,34
3,34
3,87
4,91
6,78
8,45
Total Net Cooling Capacity
(1)(6)(7)
kW
1,6
2,31
3,3
3,82
4,87
6,72
8,36
Sensible capacity in cooling mode
-1
kW
1,32
1,75
2,39
2,81
3,58
4,48
6,1
Net sensible cooling capacity
(1)(6)(7)
kW
1,29
1,72
2,35
2,75
3,53
4,41
6,01
Net latent power in cooling
(1)(6)(7)
kW
0,31
0,59
0,95
1,06
1,33
2,31
2,35
Max water flow
-1
m³/h
0,08
0,11
0,16
0,19
0,23
0,32
0,4
Pressure Drop in cooling mode
-1
kPa
6,9
7,4
9,3
12,1
14
14,2
25,7
Total capacity (heating mode)
-2
kW
1,77
2,39
3,24
3,79
4,98
6,34
8,45
Total Net Heating Capacity
(2)(6)
kW
1,8
2,42
3,28
3,85
5,03
6,41
8,55
Water flow in heating mode
-2
m³/h
0,09
0,12
0,16
0,18
0,24
0,31
0,41
Pressure drop in heating mode
-2
kPa
8,1
6,8
7,8
10,3
12,8
11,2
19,3
Sound Pressure
-3
dB(A)
31
31
36
40
31
31
39
Sound Power
(4)(7)
dB(A)
40
40
45
49
40
40
48
MAX SPEED
Fan Power Input
-1
W
57
44
68
90
77
120
170
Air flow rate
-1
m³/h
610
520
710
880
1140
1500
1820
Total capacity in cooling mode
-1
kW
1,98
2,68
4,33
5,02
6,15
9,5
11,1
Total Net Cooling Capacity
(1)(6)(7)
kW
1,92
2,64
4,27
4,93
6,08
9,39
10,9
Sensible capacity in cooling mode
-1
kW
1,64
2,04
3,18
3,74
4,59
6,47
8,25
Net sensible cooling capacity
(1)(6)(7)
kW
1,58
2
3,11
3,65
4,52
6,35
8,08
Net latent power in cooling
(1)(6)(7)
kW
0,34
0,64
1,15
1,28
1,56
3,03
2,83
Max water flow
-1
m³/h
0,09
0,13
0,21
0,24
0,29
0,45
0,53
Pressure Drop in cooling mode
-1
kPa
9,8
9,5
14,9
19,4
21
26,2
41,9
Total capacity (heating mode)
-2
kW
2,18
2,76
4,3
5,06
6,42
9,12
11,5
Total Net Heating Capacity
(2)(6)
kW
2,24
2,8
4,37
5,15
6,5
9,24
11,7
Water flow in heating mode
-2
m³/h
0,11
0,13
0,21
0,24
0,31
0,44
0,56
Pressure drop in heating mode
-2
kPa
11,9
8,7
12,7
17,1
19,9
21,3
33,8
Sound Pressure
-3
dB(A)
40
36
44
50
39
44
49
Sound Power
(4)(7)
dB(A)
49
45
53
59
48
53
58
SIZE AND WEIGHT
A
-5
mm
575
575
575
575
820
820
820
B
-5
mm
575
575
575
575
820
820
820
H
-5
mm
275
275
275
275
303
303
303
Operating weight
-5
kg
22
22
24
24
36
39
39
Summary of Contents for a-CXW 1102
Page 72: ...XXXXXXXX...