38
P1934E/EN 2009-04
en03c381.fm, 23.04.2009
Programming
3
3.3.5
Standard Application Builder / Advanced Parameters
c00
28
3en
.b
mp
Fig. 3-9: Advanced parameters
advparam.txtS
The user can enter the Advanced Parameters using the
Advanced
<F3> Softkey from the
Parameter screen. These parameters are identical regardless of the selected Fastening
Sequence.
The
Next Stage
<F2> key will increment to the next stage until it reaches the last stage with a
selected Sequence. It will then rollover to the first stage. In order to add a stage without a
selected Sequence, the user must highlight the stage field and enter a number from 1-6.
Timers
Start delay time [mS] =
Time delay before the start of the stage.
Start spike time [m] =
Time delay for the control system to start measuring torque after the stage
starts.
Max Fastening [ms] =
Maximum time for the rundown in this Stage.
End delay time [ms] =
Time delay from the tool turnoff until the torque measurement ends.
Others
Torque Filter Factor =
for calculating torque mean value.