NOTE
If you use Ethernet, port 4001 must not be blocked by a firewall, etc.
RF Communica-
tion
Select
None
if you want to use infrared data transmission only.
NOTE
You must press the <F1> softkey to apply the settings you have modified.
64
P1934E/EN 2009-04
en03c381.fm, 23.04.2009
Programming
3
3.7.6
868 MHz data transmission
For 17BPR… and 47BAR… series tools with 868 MHz data transmission, wireless data transmis-
sion is possible instead of, or in addition to, infrared data transmission.
If an infrared connection and a wireless connection exist simultaneously, the infrared connection
takes priority.
The wireless parameters are configured manually on the tool, using the function keys, in the
Radio settings
submenu.
The following three parameters are used to define the wireless data transmission between the
base station and the tool.
Parameter
Range
Radio channel
868 MHz: 1–3
Network ID
1–16
Tool ID
1–4
The radio channel and the network ID are required once for each base station. The tool ID differs
for each tool connected to a base station. If multiple systems in the same vicinity use the same
radio channel, each system must have a different network ID. If multiple base stations are in
close proximity to each other, they should use different radio channels rather than different net-
work IDs.
The channel, network ID and tool ID of the tool and the TMEB-200 / TMEB-COM / TMEC must
match.