en03c381.fm, 23.04.2009
P1934E/EN 2009-04
79
Programming
3
3.10
Diagnostics
3.10.1
Inputs / Outputs – only for TMEB-200 / TMEC
c002
98
en
.bm
p
Fig. 3-36: Inputs / Outputs
opaldiag.txtS
The External I/O are available at the Phoenix connectors.
This screen will give a live update of all system I/O. If a green box is shown next to the I/O
description, then it is active.
Otherwise the space next to the I/O description will be blank indicating it is inactive.
The display for Diagnosis Inputs/Outputs shows the status of the +24V digital inputs/outputs. The
tool number allocated to the signal appears on the right of the signal.
opaldiag.txtE