en01c381.fm, 23.04.2009
P1934E/EN 2009-04
11
Getting started
1
1.7
Communication with cordless EC tool
Before initial operation of the tool, ensure that the battery is securely in place.
After you press and release the start button, the LCD display reads
Ready
. The tool is now ready
for communication. Place it in the tool holder.
Click on the ship's wheel (Navigator button) again to display the Navigator Menu. Call up the
Communication - Tool
screen to register the tool with the connected interface, acknowledging the
Tool not connected...
warning message.
Under
Communication with the Tool
, select the interface you want to use for communication with
the tool. Press softkey <F1>,
Accept
. When the tool is switched on and connected, the tool serial
number will be shown in the
Connected tool
field. Press softkey <F2>,
Assign
. For a detailed
description, refer to 3.7.4 Communication / Tool, page 62.
Press the ship's wheel again to display the Navigator Menu.
Verify and acknowledge Tool Memory by entering Tool Setup. Press the ship's wheel to return to
the Navigator Menu.
Once Tool Setup is complete the application needs to be programmed. To do this, go to
Basic
Application Builder
.
In this screen, torque, angle, and speed parameters must be entered for the selected application.
Press the ship's wheel again to return to the Navigator Menu.
Now call up
Run Screen
. Provided the tool is switched on and in the tool holder, the message
Tool ready
is displayed in the status line. The display on the tool lights up green. The tool is now
ready to begin the first fastening cycle.
You can view the torque and angle data by pressing
Run Screen
. As you work, the screen dis-
play and the indicator lights on the tool show current results.
If you leave the tool on and place it in the tool holder, the results are transmitted to the control
system and are displayed in the Run Screen.