Programming
3
NOK interlock
Max Number of Rejects
Allows the user to enter the maximum number of rejects that
will be permitted before a release signal is required. If 0 is
entered, the function is disabled.
Release Method
Release on Backoff
allows the user to set running the tool in reverse as a release
signal.
External Input
Allows the user to set a low-high pulse to NOK Release as a
release signal.
Signal sound after NOK
[0 to 9999 milliseconds]
Defines whether after an acoustic signal is activated for the
entered time after an NOK rundown. If 0 is entered, this func-
tion is disabled.
Same for all tools
If this check box is marked, the station name and station num-
ber last entered are automatically synchronized and used for
all tools. If this check box is not marked, the station name and
the station number can be programmed separately for each
tool.
Use of this check box also impacts the serial communication
protocols Standard, Standard2 and 3964R. If
Identical for all
tools
has not been selected, the transmitted 2-digit ASCII tool
number from the
Station number
field is used. If
Identical for
all tools
has been selected, the transmitted 2-digit ASCII tool
number is hard-coded as
01
or
02
, depending on the tool from
which the rundown data originate.