en03c381.fm, 23.04.2009
P1934E/EN 2009-04
45
Programming
3
To setup a linking strategy, a Tightening Group 1-8 should be selected and given a name. This
will designate which linking strategy is being used. The user can also program if the linking strat-
egy should reset to position 1 after an NOK or set the number of times a fastener can be retight-
ened after an NOK before advancing to the next position. Up to three repetitions are permitted.
To allocate the Application to the corresponding step, enter a corresponding number (1-255) in
the
Application
field. If necessary, you can also assign a fastening location number as well as a
designation for each step. Pressing
Add
<F1> adds the selected Application as the last step.
Pressing
Delete
<F2> removes the last step. Once Linking is enabled, the controller will automat-
ically run from position 1 to the last programmed position. Note that the tool start switch or
remote start input will have to be toggled between positions. The Tightening Group and Position
will also be displayed on the Run Screen.
The following inputs and outputs will also be active when Linking is enabled: Outputs: Linking
OK, Linking NOK, Linking complete.
Inputs: Reset Linking. Please refer to the Inputs and Outputs section for more information on
these signals.
linking.txtE
3.4.5
Advanced / System Settings
c0
031
3e
n.b
m
p
Fig. 3-16: System Settings
sysset.txtS
From the System Settings Screen the user can configure parameters pertaining to the system.
General
Allows the user to assign an identifying name and number to the TME controller. This information
will be used when sending and printing data.
Station Name
(10 characters - alphanumeric)
Station Number
(10 characters - alphanumeric)