Verify that the base platform is clean, dry, and free of debris.
Install the isolation mat onto the pole base platform.
Using two people, lift the cabinet (with battery compartment) or
battery compartment riser onto the base platform, aligning the
mounting holes in the base with the counterpart holes in the
platform.
Pull the earth ground wire into the cabinet or riser through one of the cable entry ducts.
Anchor the cabinet or riser to the base platform as follows:
a.
Get (4) anchor bolts, (4) flat washers, and (4) lock washers from the installation kit.
b.
Install (1) anchor bolt, (1) flat washer and (1) lock washer into each of the four mounting holes.
c.
Tighten the bolts to secure the cabinet to the pad.
Verify that the doors open and close freely. If necessary, use shims to level the cabinet or riser.
Note:
If you removed the doors previously, re-install them to check door swing alignment.
Apply silicone caulking to the bottom perimeter of the cabinet or riser.
Note:
To complete the installation, install the top bracket to secure the cabinet to the pole. See Installing the
Mounting Fixture on a Pole for instructions.
Step 1:
Step 2:
Step 3:
Step 4:
Step 5:
Step 6:
Step 7:
To install the cabinet (or riser) onto the pole-mount fixture