123
FieldSmart
®
Fiber Active Cabinet (FAC) 400
__________________________________________________________
Installation Manual
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • [email protected]
Manual 020419 REV A - Feb 2019
Checking Cable Connections
Check external cable connections at least once a year. External cables are any cable that enters the cabinet from
the outside plant.
• Visually inspect all cables for signs of physical damage. If damage is present, cables should be repaired or replaced
per local practice.
• Check all outside plant copper connections for complete and secure connection.
• Ensure that all cable management accessories provide a clean appearance. Replace any fastening devices
(i.e. cable ties) so that they include all cables being secured.
•
Check all fiber optic connectors to ensure that they are securely fastened.
•
Check all connections on the cabinet ground bar for a tight and secure fit.
• Check all protector modules to ensure that all devices are securely seated.
• Check all conduits to ensure that any material used to seal between the cable and the conduit is still present
and providing a complete seal.