Operator's Manual: Models CB-3500 & CB-5000
4-12
Wiring to the Metering Pump
WARNING:
DO NOT wire the pump directly into your building's electrical system. The pump
must be activated (receive power) from the burner via the pump electrical circuit. DO NOT wire the
pump directly to a wall outlet so that it runs continuously; this will seriously damage your metering pump and/or
furnace and may result in a fire or explosion hazard.
1.
Install the pump electrical circuit from the furnace to the metering pump location.
2.
Wire the pump circuit according to the
Metering Pump Wiring Schematic
in Appendix B at the
back of this manual.
Wiring the Furnace and Pump
WARNING:
To avoid electrical shock, make sure that power to the furnace is turned OFF before
connecting any wires. A licensed electrician should install all wiring to your furnace. All wiring must
be in accordance with the National Uniform Electrical Code and local codes. Properly size all wires and use
electrical conduit for all electrical lines.
Wiring your furnace involves the installation of two lines:
(1) A dedicated electrical line to the furnace
(2) A pump electrical circuit from the furnace to the metering pump
Necessary wiring specifications are provided in this section and in the
Wiring Schematics
located in
Appendix B
at the back of the manual.
Wiring to the Furnace
1.
Install a
dedicated electrical circuit
to the
electrical junction box on the furnace.
Refer to NFPA-70 for wire size and distances
2.
Wire the furnace according to the Wiring Schematic, Figure B1, in Appendix B.
Ensure that the
ground wire is attached to the GREEN ground screw on the furnace junction box.
3.
Check for correct voltage at the furnace, and refer to the following chart.
ATTENTION:
Incorrect voltage will severely damage the blower motor/furnace components.
DO NOT operate your furnace on any non-specification power system.
Model
Voltage
Breaker Size*
Circuit
Hertz
CB-3500
208/240
30/30 amps
Dedicated
60
CB-3500 (w/Options) 208/240
35/35 amps*
Dedicated
60
CB-5000
208/240
30/30 amps
Dedicated
60
CB-5000 (w/Options) 208/240
35/35 amps*
Dedicated
60
WARNING:
DO NOT tie into
an
existing
circuit, or electrical
overload may occur.
*NOTE:
When installing any optional equipment (e.g. air compressor or draft inducer), please
refer to the "w/Options" breaker size above. Make sure a qualified electrician properly sizes and
installs this electrical circuit.
Refer to NFPA-70 for wire size and distances.
4.
DO NOT turn on main power until instructed to do so.
Summary of Contents for CB-3500 series
Page 2: ......
Page 18: ...Operator s Manual Models CB 3500 CB 5000 1 10 ...
Page 36: ...Operator s Manual Models CB 3500 CB 5000 3 16 ...
Page 68: ...Operator s Manual Models CB 3500 CB 5000 5 6 ...
Page 74: ...Operator s Manual Models CB 3500 CB 5000 6 6 ...
Page 94: ...Operator s Manual Models CB 3500 CB 5000 9 10 ...
Page 102: ...Operator s Manual Models CB 3500 CB 5000 10 8 ...
Page 107: ...Operator s Manual Models CB 3500 CB 5000 A 5 ...
Page 126: ...Operator s Manual Models CB 3500 CB 5000 A 24 ...
Page 134: ...Operator s Manual Models CB 3500 CB 5000 C 2 ...