Operator's Manual: Models CB-3500 & CB-5000
3-11
Installing the Burner
Checking the Burner Nozzle and Electrodes
NOTE:
The burner nozzle is factory installed. Model CB-3500 uses a Delavan 9-5 nozzle. Model
CB-5000 uses a Delavan 9-11 nozzle. The nozzle size is indicated on the nozzle head as shown in Figure 3H.
Refer also to
Appendix A
at the back of the manual for additional specifications/instructions on the burner nozzle.
NOTE:
Check the electrode settings as specified in Figure 3H. The electrode settings must be correct for your
burner to operate properly.
Figure 3H - Burner Nozzle and Electrode Specifications
BURNER NOZZLE
VIE
W - BB
3X
NOZZLE IS STAMPED WITH SIZE
ON FLAT OF NOZZLE HEAD
CRITICAL DIMENSION:
NOZZLE MUST BE 1/8"
AHEAD OF THE DISK.
NOZZLE MUST NOT BE
BEHIND THE DISK.
FRONT VIEW - BB
VIE
W - AA
1/8"
SPARK
GAP
I88647
3/16" GAP BETWEEN
ELECTRODES & NOZZLE
SIDE VIEW - AA