MOTORIZED WHEEL BALANCER WITH DIGITAL DISPLAY
If during machine calibration there are some anomalies, error codes will be displayed (e.g. Err 025). See chapter
Error Codes and act accordingly to eliminate the problem and to continue/repeat/cancel the calibration in
progress.
The launches interrupted by pressing [P10] Stop or by raising the wheel guard may be repeated by pressing [P8]
Start or by lowering the wheel guard.
How to exit the CAR/SUV Wheel Type calibration
You can exit the ongoing calibration procedure at any time by pressing [F + P3]. The machine will return to the
SERVICE mode displaying the writing SER SER. To return to the NORMALE mode, press [F+P3] again.
The calibration procedure in progress will be cancelled and the balancing results will use previous calibration
values.
Calibration according to the MOTO Wheel Type
Calibration for the MOTO Wheel Type (wheels for motorbikes) is completely separated from the machine calibration
for the CAR/SUV Wheel Type because it takes into account the fact that the machine uses a special fl ange for
motorcycle wheels that slightly alters the balancing of the shaft.
If MOTO Wheel Type calibration has not been carried out and you try to run a
balancing launch when the MOTO Wheel Type is selected, the machine will not
run the launch and will display the error code ERR 03.
To calibrate motorbike wheels, proceed as follows:
1. Switch the machine on;
2. Apply the fl ange on the shaft for motorbike wheels as shown in Figure F4.1.
Figure F4.1. Application of the motorbike fl ange onto the
shaft. Align the writing “Cal” on the fl ange and on the fl ange for motorbikes
3. Press [F+P3]. The writing SER SER will be displayed (this means that we have entered the SERVICE mode);
4. Press [P3] . The writing CAL CAR (calibration for auto-vehicle and off-road vehicle wheels) will be displayed;
5. To select the MOTO (motorbike wheel) calibration type, press [P4] or [P5]. When the MOTO calibration type
is selected, the machine automatically loads the geometric data of the
motorbike fl ange and automatically sets the MOTO Wheel Type and the ALU1 programme.
6. Press [P3] to confi rm. The writing CAL0 will be displayed;
7. Press [P8] Start or lower the wheel guard: the machine will run a launch;
8. At the end of the launch, the machine will display the writing h12 CAL.
Apply the calibration weight on the internal side as shown in Figure F4.2.
The calibration weight is to be applied on the hole that has the writing “CAL”
marked on it;
Figure F4.2. Application of sample weight on
the internal side of the motorcycle fl ange on the shaft (Cal2 phase)
9. Bring the motorcycle fl ange in perfect vertical position with the calibration
weight at the top part as shown in fi gure F4.2 and press the [P8] Start or
lower the wheel guard.