EQ 1000
MOTORIZED WHEEL BALANCER WITH DIGITAL DISPLAY
UFc Converter voltage-frequency test
The converter voltage-frequency test shows two numbers on the displays that represent the values of the
internal conversion to the CPU-C1 electronic control circuit board. These values are used by technical support
personnel to determine the functioning state of the circuit board. To exit the test programme, press [F+P9].
Ret Returns to the Service mode
This Test Programme menu option sets the machine back to the SERVICE mode
SIGNALS
Error codes
The machine reports error conditions by showing an error code on the display. The list of the error codes is shown
in table T10.1.
Table T10.1 – Error codes
Error code
Description
Notes
000 to 009
Machine parameters
Contact technical support.
010
Reverse rotation of the wheel
Contact technical support.
011
Wheel speed too low
Check the mains voltage. If the checks do not lead to any
results, contact technical support.
012
The wheel cannot be stopped at the end of the launch Check the mains voltage. If the checks do not lead to any
results, contact technical support.
013
Wheel speed too high
Contact technical support.
014
The wheel does not spin
Contact technical support.
015
Keys pressed or jammed at start-up
Release all buttons, then turn off or restart the machine. If the error
persists, contact technical support.
016
Distance sensor not in rest position when the machine
is switched on
Set the sensor to its rest position: the error should disappear.
If the error persists, contact technical support.
017
Width sensor not in rest position when the machine
is switched on
Set the sensor to its rest position: the error should disappear.
If the error persists, contact technical support.
018
Reserved
019
Communication processor failure
Turn the machine off or on. If the error persists, contact technical
support.
The machine can still be used but all functions related to the
USB port are disabled.
020
Lack of communication with the eeprom memory
Turn the machine off and then on again. If the error persists,
contact technical support.
021
Lack of machine calibration data or incorrect calibration
data
Carry out calibration for the CAR/SUV Wheel Type and/or for
the MOTOWheelType. If the error persists, contact technical
support.
See also ERR030 and ERR031.
022
Pick-up channel A too high
Excessive imbalance or anomaly. Turn the machine off and then
on again. If the error persists, contact technical support
023
Pick-up channel A too high
Excessive imbalance or anomaly. Turn the machine off and then
on again. If the error persists, contact technical support
024
Pick-up channel A too high
Excessive imbalance or anomaly. Turn the machine off and then
on again. If the error persists, contact technical support
025
Presence of weight during the Cal0 calibration phase Remove the weight and repeat the launch of the Cal0 phase. If
the error persists, contact technical support