EQ 1000
MOTORIZED WHEEL BALANCER WITH DIGITAL DISPLAY
TROUBLESHOOTINGS
Below is a list of faults that may occur and that the user can solve if the cause is found among those indicated.
For any other malfunction or fault call in the technical support centre.
Machine does not switch on (monitor remains switched off)
No power at the socket.
- Make sure that the mains power is present.
- Check the electrical power circuit in the workshop.
The machine plug is defective.
- Check if the plug is working properly and replace it if necessary.
One of the FU1-FU2 fuses of the rear electrical panel has blown.
- Replace the blown fuse.
The monitor has not been switched on (only after installation).
- Switch on the monitor by pressing the button located on the front of the monitor.
The monitor's power supply connector (located on the rear of the monitor) is not correctly inserted.
- Check for proper insertion of the connector.
START has been pressed and the wheel fails to spin (the machine does not start)
The wheel guard is raised (the "A Cr" message is displayed).
- Lower the guard.
The wheel balancer provides unsteady unbalance values
The machine was jolted during the spin.
- Repeat the wheel spin while making sure that nothing affects machine operation while acquisition is in progress.
The machine does not fi rmly rest on the fl oor.
- Make sure that the fl oor support is fi rm.
The wheel is not locked correctly.
- Tighten the locking ring nut fi rmly.
Several spins are to be performed to balance the wheel
The machine was jolted during the spin.
- Repeat the wheel spin while making sure that nothing affects machine operation while acquisition is in progress.
The machine does not fi rmly rest on the fl oor.
- Make sure that the fl oor support is fi rm.
The wheel is not locked correctly.
- Tighten the locking ring nut fi rmly.
- Make sure that the accessories used for centring are suitable and original.
The machine has not been calibrated correctly.
- Perform the sensitivity calibration procedure.
The entered geometric data are not correct.
- Make sure that the entered data correspond to the wheel dimensions and correct them if necessary.