[SMB-66E]
-
7
-
OPERATION
2
9) Enter the traveling time per segment and press
.
Setting range: 0.01 to 20 (T-type)
Setting range: 0.01 to 100 (Other)
※
※
※
※
The maximum rotation speed is checked
according to the number of segments, traveling
time and cam curve.
If the maximum rotation speed exceeds the
operating range, the following message is
displayed
and
the
traveling
time
is
automatically corrected.
After confirming, press
.
[Example of correction of traveling time, cam curve and indexing time]
•
Enter the MS curve, 6 segments and traveling
time 0.15 seconds. The maximum rotation
speed exceeds 100rpm and therefore the time
is automatically corrected to 0.18 seconds.
Note: For systems where the maximum rotation
speed is 100rpm
•
Enter the MS curve, 6 segments and traveling
time 0.18 seconds and perform parameter change
to change to the MC curve. The traveling time
does not change to maximum speed 0.13
seconds.
※
※
※
※
The maximum rotation speed varies according to the actuator.
100rpm
0.18sec
0.15sec
100rpm
0.13sec
0.18sec
EQL SEG: MOV’G
TIME[ ]SEC
★
To correct the traveling time to 0.53
seconds after calculation
MOV’G TIME KEY
PRESS RTN KEY
MOV’G TIME REV
TO 0.53 SEC
PRESS RTN KEY
Alternately displayed
Alternately displayed
EQL SEG: MOV’G
TIME[ 0.53]SEC