Logical Object: OTS
The NO-SHARED-CIPHERS alarm is raised when the certificates with different encryption cipher or algorithm
are provisioned on either the server or the client.
Clear the NO-SHARED-CIPHERS Alarm
Verify the same encryption cipher or algorithm is provisioned on both the server and the client.
If the alarm does not clear, log into the Technical Support Website at
http://www.cisco.com/c/en/us/support/index.html
for more information or call Cisco TAC (1 800 553-2447).
NON-CISCO-PPM
Default Severity: Minor (MN), Non-Service-Affecting (NSA)
Logical Object: PPM
The Non-Cisco PPM Inserted condition occurs when a PPM that is plugged into a card port fails the security
code check. The check fails when the PPM used is not a Cisco PPM.
Clear the NON-CISCO-PPM Condition
SUMMARY STEPS
1.
Obtain the correct Cisco PPM and replace the existing PPM with the new one.
DETAILED STEPS
Obtain the correct Cisco PPM and replace the existing PPM with the new one.
If the condition does not clear, log into the Technical Support Website at
http://www.cisco.com/c/en/us/support/index.html
for more information or call Cisco TAC (1 800 553-2447).
NODE-FACTORY-MODE
Default Severity: Critical (CR)
Logical Object: NE
The Node Factory Mode alarm is raised when the database is not available due to the following:
• New installation.
• Reset NE to factory defaults.