Section 4: Troubleshooting
E Series 675/775 Service Manual
4-1
020-000546-04 Rev. 1 (04-2017)
4 Troubleshooting
4.1
LED Status
The LED status indicators are located on the rear of the projector. Each LED is defined below.
Table 4.1 Lamp 1 LED
PROJECTOR STATE
LED STATUS
Failed to strike lamp after 5 attempts (strike attempts will stop).
Lamp has unexpectedly shut down (system goes into cool down state).
Red (short blink)
Lamp time has expired and lamp should be replaced. (projector also begins to display
the replace lamp OSD message at startup).
Yellow (solid)
Lamp 1 turn ON ok.
Green (solid)
Projector is switching to Lamp 1 (Lamp 2 is off)
(selected by OSD menu “Current Lamp”: 1/ 2/ Both)
Green (short blink)
Lamp is off
Off
Table 4.2 Lamp 2 LED
PROJECTOR STATE
LED STATUS
Failed to strike lamp after 5 attempts (strike attempts will stop).
Lamp has unexpectedly shut down (system goes into cool down state).
Red (short blink)
Lamp time has expired and lamp should be replaced. (projector also begins to display
the replace lamp OSD message at startup).
Yellow (solid)
Lamp 2 turn ON ok.
Green (solid)
Projector is switching to Lamp 2 (Lamp 1 is off)
(selected by OSD menu “Current Lamp”: 1/ 2/ Both)
Green (short blink)
Lamp is off
Off
Table 4.3 Status LED
PROJECTOR STATUS
LED STATUS
Projector is in OFF state (without AC connected)
Off
Projector is in standby mode (AC connected)
Yellow (solid)
Projector is in startup state
Yellow long blink
Projector is in cool down state
Yellow long blink
Summary of Contents for DHD675-E
Page 1: ...E Series 675 775 S e r v i c e M a n u a l 020 000546 04...
Page 2: ......
Page 3: ...E Series 675 775 S e r v i c e M a n u a l 020 000546 04...
Page 12: ......
Page 32: ......
Page 108: ......
Page 110: ......
Page 112: ......
Page 113: ...Appendix C Schematic Diagrams E Series 675 775 Service Manual C 3 020 000546 04 Rev 1 03 2017...
Page 121: ......