![background image](http://html1.mh-extra.com/html/christie/dhd675-e/dhd675-e_service-manual_2603820023.webp)
Section 3: Service Setup
E Series 675/775 Service Manual
3-7
020-000546-04 Rev. 1 (04-2017)
4. Select
Sequence Code
and use the
E
NTER
key to select
0(2x,0)
.
5. Select
Wave Form
and use the
E
NTER
key to select
4(4-147,4-147)
.
6. Select
Color Wheel Index
and use the
L
EFT
and
R
IGHT
keys to make the gray levels
look smooth.
7. Check the 64 Gray RGBW pattern to ensure level changes are smooth.
8. Select
Color Speed
and use the
E
NTER
key to select
3X
.
9. Select
Sequence Code
and use the
E
NTER
key to select
0(3x,0)
.
10. Select
Wave Form
and use the
E
NTER
key to select
6(6-149,6-149)
.
11. Select
Color Wheel Index
and use the
L
EFT
and
R
IGHT
keys to make the 255 Gray Level pattern look
smooth.
12. Check the 64 Gray RGBW pattern to ensure level changes are smooth.
Inspection Item
255 Gray Level and 64 Gray RGBW patterns appear normal.
Criteria
Smooth gradations in patterns. No obvious steps in gray levels.
255 Gray Level
Gradations Smooth
Gradations ‘Stepped’