71
DWU951 (DD1-WU80P/81P) / DWX951 (DD1-WX80P/81P) / DXG1051 (DD1-X100P/101P)
DWU951/DWX951/DXG1051 Service Manual
020-000674-01 Rev.1 (01-2014)
Page 71 / 118
䖃
Ballast cover
(BALLAST FAN)
Torque: 0.68-
0.88N
䞉
m
T3x12
black
screws
Disassembling
1) Remove 4 screws to detach the ballast cover. Put away CNBL2 and BALLAST FAN cable from the
holes on the ballast cover carefully.
2) Remove the BALLAST FAN.
Assembling & wiring
1) Attach the BALLAST FAN in place.
2) Attach the ballast cover on the ballast holder. Wire CNBL2
and BALLAST FAN cable through the holes on the cover as
below.
3) Wire CNLP2, CNPF2, CNBL2 and BALLAST FAN cable as
below. Attach the ballast shield-R and screw down.
ATTENTION
Make sure the direction
BALLAST
FAN
Air Flow
Ballast cover
Ballast holder
BALLAST
FAN
Wire CNLP1 through this clamp
Wire CNPF1/2 and CNLP1
through this clamp
CNLP1
CNPF1
CNPF2
BALLAST
SHIELD-R
Wire CNPF1 on the left side and CNPF2 on the
right side. And wire them under the shield metal
as below.
Ballast
cover
Wire the BALLAST
FAN cable through
this hole
Wire CNBL2 through
this hole
OK
NG
[CAUTION]
Wire CNPF2 without folding near
the connector.
Wire
CNPF2 on
CNLP2
M3x8 silver screws
Torque: 0.68-0.88N
䞉
m
BALLAST
SHIELD-R
Wire CNPF1/2