43
DWU951 (DD1-WU80P/81P) / DWX951 (DD1-WX80P/81P) / DXG1051 (DD1-X100P/101P)
DWU951/DWX951/DXG1051 Service Manual
020-000674-01 Rev.1 (01-2014)
Page 43 / 118
Status Monitor
Indicator
Description
current
status
log
POWER
TEMP
Front
LAMP-1
Front
LAMP-2
Rear
LAMP-1
Rear
LAMP-2
COVER 1 COVER ERR
Lights
In Red
off
Blinks
In Red
Blinks
In Red
off
off
Projector has detected LAMP COVER ERROR.
Refer to the section "Regarding the indicator lamps".
FAN**
2 FAN ERR **
Lights
In Red
Blinks
In Red
off
off
off
off
Projector has detected FAN ERROR.
Refer to the section "Regarding the indicator lamps". The
fan in failure indicated with “FAN**” is as below;
FAN1: Lamp 1 exhaust fan FAN6: Lamp 2 down fan
FAN2: Lamp 1 up fan
FAN7: Power exhaust fan
Q>"^ #
Q>"©^* #
FAN4: Lamp 2 exhaust fan FAN9: Ballast fan
FAN5: Lamp 2 up fan
FAN10:Iris fan
The location of each fan is shown below this table.
LAMP
3 LAMP ERR
Lights
In Red
off
Lights
In Red
Lights
In Red
Projector has detected LAMP ERROR.
Refer to the section "Regarding the indicator lamps".
TEMP
4 TEMP ERR
Lights
In Red
Lights
In Red
off
off
off
off
Projector has detected TEMPERATURE ERROR.
Refer to the section "Regarding the indicator lamps".
AIR
5 AIRFLOW ERR
Lights
In Green
off
off
off
off
off
Projector detected AIR FLOW WARNING.
Refer to the section "Related Messages" according to the
OSD.
COLD
** COLD ERR
D.C.
Alternately
off
off
Projector detected COLD WARNING.
Refer to the section "Regarding to the indicator lamps".
The head number "**" of the text indicates which has the
problem;
7: outside temperature, SENSOR-A PCB
10: inside temperature, SENSOR-B PCB
Blinks
In Red
In Red
FILTR
8 FILTER ERR
D.C.
Simultaneously
off
off
Projector detected FILTER WARNING.
Refer to the section "Regarding the indicator lamps".
Blinks
In Red
In Red
SHUTR 15 SHUTTER ER
D.C.
D.C.
D.C.
D.C.
D.C.
D.C.
The mechanical lens shutter cannot open.
If the cable connection is OK, replace the SHUTTER UNIT.
SHIFT
16 SHIFT ERR
D.C.
D.C.
D.C.
D.C.
D.C.
D.C.
#
If the cable connection is OK, replace the ENGINE
assembly.
LAMP1
19 LAMP1 ERR
D.C.
D.C.
Lights
In Red
off
Lights
In Red
off
Projector has detected LAMP1 WARNING.
Refer to the section "Regarding the indicator lamps".
LAMP2
33 LAMP2 ERR
D.C.
D.C.
off
Lights
In Red
off
Lights
In Red
Projector has detected LAMP2 WARNING.
Refer to the section "Regarding the indicator lamps".
HUMID
65 HUMID ERR
Lights
In Green
off
off
off
off
off
Projector detected HUMID WARNING.
Refer to the section "Related Messages" according to the
OSD.
OTHER ** OTHER ERR
Lights
In Red
Alternately
D.C.
D.C.
Projector has detected OTHER ERROR (miscellaneous
errors) in the ENGINE assembly.
Refer to the section "Regarding the indicator lamps".
The head number "**" indicates the portion which has
problem.
85: the humid sensor is out of order.
67: the Peltier device is out of order.
68: the temperature error of heat pipes
86: the temperature sensor error of heat pipes
80: both color wheels are out of order
81: the color wheel slider is out of order
In Red
In Red
Lights
In Red
Simultaneously
D.C.
D.C.
Blinks
In Red
In Red
C.WHL
82 C.WHEEL ER
D.C.
Alternately
D.C.
D.C.
Projector has detected COLOR WHEEL WARNING.
Refer to the section "Regarding the indicator lamps".
Flashes
twice
Flashes twice
?& &K #
according to the following table.
Summary of Contents for DD1-WU80P
Page 1: ...DWU951 DWX951 DXG1051 Service Manual 020 000674 01...
Page 2: ......
Page 149: ......
Page 150: ......