Mounting the Remote Power Rack Shelf
The power system must be mounted in a clean and dry environment. Sufficient free space must be
provided at the front and rear of the power system.
Warning! If not avoided, the following could result in death or serious injury.
•
This product must be installed within a restricted access location not accessible by the general
public.
1. Find a location in the rack for a 3U device.
2. Attach the Remote Power Rack Shelf to the rack.
To ensure a proper electrical bond between the system chassis and the relay rack use thread-
forming mounting screws and star washers.
Inserting the power modules into the Remote Power Rack
Shelf
The power modules, or rectifiers, convert an AC power source into the DC current required by the
product.
1. Remove the cover from the rectifier slot.
2. Slide the power module into the front of the chassis until it clicks into place.
3. To lock the power module, lift the handle and snap it into place.
4. Repeat steps 1 to 3 for each rectifier in the Remote Power Rack Shelf.
Connecting the LCD display panel power cables to the
Remote Power Rack Shelf
To power the FHD553-XE-R and FHD553-XE-HR panels, connect the cables between the LCD panels
and the Remote Power Rack Shelf.
1. Connect the main power cable to the Remote Power Rack Shelf.
2. Connect the LCD panel cable to the main power cable.
If the power cord supplied with your product is not long enough to connect the first display
panel in an array to the Remote Power Rack Shelf module, you must purchase a power cord of
an adequate length. Christie recommends one of the pre-terminated power cables offered as
Christie accessories, or that you create a custom cable using the Christie Main Power Cable
Spool (P/N 154-122106-XX), Connector Kit (P/N 154-125109-XX), and Molex Crimping Tool
(P/N 154-124108-XX). For more information on the Molex Crimping Tool, see the Molex
documentation.
3. To connect one display panel to another, connect the DC daisy-chain power cord to the Out
port of a panel, then connect the other end of the power cord to the In port of another panel,
within specified system limits.