2-2
2.2 Mounting Method to Panel
1. Panel cutout size
Standard product
Alumimum die-cast door (option)
Unit: mm
Single unit mounting…..
Same as in the standard product
Lateral tight mounting instrumentation
n : Number of units
2. Mounting method
1) Insert the instrument into the panel cutout
from the front of the panel.
2) Fix the instrument to the panel by the mounting
brackets (Tightening torque 1.0 N.m ). Fix the
mounting brackets at 2 positions on the upper and
lower faces.
(144×n)-6
+2
0
138
+1
0
138
+1
0
200
200
138
+1
0
This instrument is designed to be mounted on a panel.
Use a panel made of a steel plate of 2 mm to 6 mm in thickness.
Mount the instrument on a panel
Warning
Panel thickness
(2 to 6 mm)
Mounting bracket
Mounting bracket