- 23 -
(2) RS422A
Connection between a line converter and the unit
Cable
Crimp type ring terminals
↔
Crimp type ring terminals
RS422A
cable
(for a line converter)
Shape
4-core cable of twisted 2-core cables of twisted VCTF lines. Each side has a SG
(signal ground) line. Since the line converter has no SG terminal, cut and use the
cable.
Internal
wiring
Model
code
R Z - C R A 2
□□
Cable length: 01 to 99m (specified)
Connection between the unit and other devices
Cable
Crimp type ring terminals
↔
Crimp type ring terminals
RS422A
cable (for parallel)
Shape
4-core cable of twisted 2-core cables of twisted VCTF lines. Each side has a SG
(signal ground) line.
Internal
wiring
Model
code
RZ - CRA 1
□□
Cable length: 01 to 99m (specified)
Line converter side
Recorder side
RDB
RDA
SDA
SDB
SG
SDB
SDA
RDA
RDB
SG
Device side
Recorder side
SDB
SDA
RDA
RDB
SG
SDB
SDA
RDA
RDB
SG
(black)
(white)
(red)
(green)
(blue)
RDA
RDB
SDA
SDB
SG
SDA
SDB
RDA
RDB
SG
(black)
(white)
(red)
(green)
(blue)
(black)
(white)
(red)
(green)
(blue)
SDA
SDB
RDA
RDB
SG
SDA
SDB
RDA
RDB
SG
(black)
(white)
(red)
(green)
(blue)