17 / 39
FISIOLASER IRD/IRD 2
! WARNING !
It is recommended to clean with caution the equipment and the accessories supplied
after every treatment and before their use on other patients .
The cleaning and relative disinfection must have effected in a systematic way ,
before the execution of the therapeutic treatment which to submit the patient .
DESIGNATED USE
The FISIOLASER IRD-series unit is a electro-medical device that delivers laser-
therapy treatments, with the help of mono-diode and multi-diode probes for the
provision of treatment .
The use of FISIOLASER IRD-series unit is reserved , under the supervision and
responsibility of an expert in the problems of the laser radiation, for operators such
as physiatrists, physiotherapists and pain therapists,that , by their training, provide
assurance of proper use and safe for the patient .
In fact, the operator must be appropriately qualified and carefully studied the
contents of the user manual in order to use the device; or, it must operate under the
supervision of a health professional adequately qualified to use the machine, able to
understand the benefits and the limits of therapy and to work in conditions of safety
for the person undergoing treatment.
Such equipment can be used in hospital environment outpatient; nevertheless, it is
important to know that the user follow the medical instructions to use the equipment
or that he follow the indications present in the user’s manual.
Different types of pain in different areas .
Inflammatory disorders of the tendons and soft tissues (tendonitis, bursitis,
enthesitis), insertional disorders, superficial limb pain.
Assists in the treatment of ulcers and bedsores. In scars and treatment of oedema .
BEST USE
! WARNING !
In order to guarantee an absolutely safe operation
of the unit on the patient, it is advisable to carry out periodical inspections (at 2
years intervals).
! WARNING !
Do not use your FISIOLASER IRD-series unit in
the presence of flammable anaesthetic mixture ;
in the event of default , CHINESPORT SpA
shall not be consider responsible for any accidents
! WARNING !
Do not use your FISIOLASER IRD-series unit
in the presence of flammable materials
( for example , paper ) ; in the event of default , CHINESPORT SpA shall not be
consider
responsible for any accidents
! WARNING !
Do not use your FISIOLASER IRD-series unit in
the presence of oxygen-rich environments ;
in the event of default , CHINESPORT SpA
shall not be consider responsible for any accidents
! WARNING !
The laser therapy treatments must be provided,
under the strict control of the operator,
to patients conscious , able to interact with
the operator in response to stresses transmitted
by the device ; in case of default to the indications
given , CHINESPORT SpA shall not be consider responsible for any accidents
! WARNING !
It is important that the operator ensures
the machine’s correct electrical installation
before turning on the device.
! WARNING !
It is recommended not to start the emission of treatment
if the device isn’t in perfect mechanical conditions .