Dual Phase Steel
This information provides repair recommendations and general guidelines for steel classified as Dual Phase Steel (dual phase steel
with a tensile strength up to and including 800
MPa), also known as DP.
General Motors recommends the following when repairing or replacing this type of steel during collision repair.
Note: The use of heat to repair damage is not recommended for this classification of steel.
Recommended Repairs
• Cold repairs can be performed on this type of steel, unless the damage includes kinks. If the damage includes kinks, the
part should be replaced.
• Sectioning or partial replacement of this type of steel is recommended only at approved locations, in a specific sectioning
procedure.
• This type of steel can be used as a sleeve, or backer plate, when recommended in a specific sectioning procedure.
• Squeeze resistance spot welding can be used to replace factory spot welds, where applicable.
• MIG plug welding and MIG stitch welding can be used on this type of steel.
• MIG brazing can be used on this type of steel.
© 2011 General Motors. All rights reserved.