16
The unit does not close automatically, it
OPENS automatically
Check setting of Dipswitch 7
Change setting of Dipswitch 7
Control board does not work with transmitter
1. Transmitter not programmed
2. A photocell blocks
1.Program transmitter
2.Check photocells
Gate can only be opened
1.Photocell blocks
2.Dip switch setting not as desired
1.Function and connection must be
checked
2.Check dip switch
The control board is not running
No covered distance learned
Learn covered distance.
See Initial operation
The gate does not open completely.
1.Is the door travel programmed
correctly?
2.Is the force adjusted correctly?
1. Program door travel again
2. Increase force (under wind load the
operator may run a bit slower)
(Remote controlled) universal receiver does not work Observe polarity (terminals 14/15)
Swap “+” and “-” cables
PE OVERRIDE:
If a safety edge or loop detector is fitted and the PE beams are not used, the PE terminals
must be terminated to com as illustrated below.
Factory installed
Resistor
All unused safety inputs
must be terminated to COM (19)
TECHNICAL DATA
Voltage IN
Frequency
Power
Current rated
Torque
Capacitor
Thermal Overload
Protection
Motor Speed
Travel Speed
Duty Cycle
Working Temperature
Range
Protection Class
Degree of Protection
Weight
approx. Gate Length
Max. Gate weight at
max. length (incl.
20% reserve)
MGS300
230-240 Vac
50Hz
300W
1.3A
9Nm
8µF
140°
1400
12
30
-20
O
C - 55
O
C
IP44
I
9
5m
300kg
MGS500
230-240 Vac
50Hz
360W
1.5A
10Nm
10µF
140°
1400
12
30
-20
O
C - 55
O
C
IP44
I
9
8m
500kg
MGS1000
230-240 Vac
50Hz
480W
2.1A
12Nm
16µF
140°
1400
11.5
30
-20
O
C - 55
O
C
IP44
I
10
10m
1000kg
The safety PE beams supplied with your kit must be fitted if no other safety is