background image

19

Liability – Australia only

Under  no  circumstances  shall  the  Seller  be  liable  for

consequential,  incidental  or  special  damages  arising  in

connection with the use, or inability to use, the Unit.  In no

event shall the Seller's liability for damages or injury arising

from breach of law or contract or for negligence, exceed the

cost  of  repairing  or  replacing  the  Unit  or  refunding  the

purchase price of the Unit.

Under  Division  2  Part  V  of  the  Trade  Practices Act,  1974,

certain warranties and conditions (Implied Terms) are implied

into contracts for the supply of goods or services if the goods

or  services  are  of  a  kind  ordinarily  acquired  for  personal,

domestic  or  household  use  or  consumption.  Liability  for

breach of those Implied Terms cannot be excluded or limited

and the limitations and exclusions above do not apply to the

Implied Terms.

Except  for  the  Implied  Terms  and  the  warranties  set  out

above,  the  Seller  excludes  all  warranties  and  conditions

implied by statute, at law, in fact or otherwise.

Liability – New Zealand only

Except  as  set  out  in  the  Fair  Trading  Act  1986  and  the

Consumer Guarantees Act 1993: 

(a)  all  other  guarantees,  warranties  and  representations  in

relation to the Unit or its supply are excluded to the extent

that the Seller can lawfully exclude them; and

(b)  under  no  circumstances  shall  the  Seller  be  liable  for

consequential,  incidental  or  special  damages  arising  in 

connection  with  the  use,  or  inability  to  use,  the  Unit,  other 

than  those  which  were  reasonably  foreseeable  as  liable 

to result from the failure.

NOTE:

We  request  that  you  attach  your  sales  docket  or

invoice to this manual to enable you to establish the date of

purchase in the unlikely event of a service call being made.

Chamberlain  reserves  the  right  to  change  the  design  and

specification  without  prior  notification.  Some  features  or

accessories may not be available in certain markets or areas.

Please check with your distributor.

Chamberlain service centres:

Australia

Phone toll free 1800 638 234

Fax toll free 1800 888 121

New Zealand

Auckland phone 09 415 4393

Phone toll free 0800 MERLIN

Fax toll free 0800 653 663

www.chamberlainanz.com

CHAMBERLAIN 2 YEAR LIMITED WARRANTY

Merlin MGS300/MGS500/MGS1000 

Sliding Gate Motor

Chamberlain  Australia  Pty  Limited  /  Chamberlain  New

Zealand  Limited  (Seller)  warrants  to  the  original

purchaser of the Merlin MGS series gate operator (Unit)

that  it  is  free  from  defects  in  material  and/or

workmanship for a period of 2 YEARS from the date of

first purchase from the Seller. 

Please retain your proof-of-purchase in the unlikely event you

require warranty service.

If,  during  the  limited  warranty  period,  the  Unit  fails  due  to

defects  in  materials  or  workmanship  Chamberlain  will,

provided  the  defective  part  or  Unit  is  returned  freight  and

insurance  prepaid  and  well  packaged  to  the  nearest

Chamberlain office or authorised installer, undertake to repair

or, at its option, replace any defective part or Unit and return

it to the Buyer at no cost. Repairs and replacement parts are

warranted  for  the  remaining  portion  of  the  original  warranty

period.

Limited warranty on motor

Chamberlain will furnish a replacement motor free of charge,

if it is found to be defective. Labour costs may apply.

Where the Unit has been installed by an authorised installer,

Chamberlain  will  furnish  replacement  parts  free  of  charge

through  the  authorised  installer.  A  service  fee  for  on-site

service may apply.

In-warranty service

During the warranty period, if the product appears as though

it may be defective, call our toll free service before removal of

the unit. A Chamberlain technician will diagnose the problem

and  promptly  supply  you  with  the  parts  for  “do-it-yourself”

repairs, or provide you with shipping instructions for a factory

repair or replacement. If an authorised installer installed your

unit you must call them for prompt on-site service.

If  our  service  centre  determines  that  a  warranty  claim  has

been made in respect of a failure or defect arising from any of

the  exclusions  set  out  below,  we  may  charge  you  a  fee  to

repair and/or return the Unit to you.

Exclusions

This warranty does not cover any failure of the Unit due to:

1. non-compliance with the instructions regarding installation,

operation,  maintenance  and  testing  of  the  Unit  or  of  any

product with which the Unit is used.

2.  any  attempt  to  repair,  dismantle,  reinstall  or  move  the

Product to another location once the Product is installed by

any person other than an authorised installer.

3.  tampering,  neglect,  abuse,  wear  and  tear,  accident,

electrical storm or water damage, excessive use or conditions

other than normal domestic applications.

This warranty does not cover any problems with, or relating to,

the gate, its hardware and fittings, track, rack or guides or any

problems caused by electrical faults, replacement of batteries

or labour charges for reinstalling a repaired or replaced Units.

Summary of Contents for Merlin MGS1000

Page 1: ...300 MGS500 AND MGS1000 and CB22 CONTROL BOARD Chamberlain Australia Pty Ltd PO Box 1446 Lane Cove NSW 1595 Phone toll free 1800 638 234 Chamberlain New Zealand Ltd PO Box 100 221 North Shore 0745 Phon...

Page 2: ...dren Never allow children to play near an operational gate After installation is complete a final test of ALL functions and SAFETY systems must be carried out Where safety devices are installed it is...

Page 3: ...des poorly is likely to need a stronger drive than a heavy smooth sliding gate NOTE Gate weight is only an approximate indicator the actual relevance of which can vary greatly Climatic conditions Gate...

Page 4: ...re that a conduit is installed before adding the concrete and that the exit point for the conduit is on the correct side of the base plate in relation to the motor The plate has two recesses ensure th...

Page 5: ...arance between drive and rack Mounting the Motor Hand tighten one of the nuts provided onto each of the four posts tighten to about 15mm from the base of the plate then place a washer provided onto ea...

Page 6: ...lex nut provided Installing the magnet and bracket for nylon rack Identify your start and stop limit Fit the bracket over the rack and tighten the screws Install the start and stop magnets as outlined...

Page 7: ...injury to person whilst the gate is moving not required if the gate recess is enclosed 9 Induction loop for safety or exit optional protects against damage to vehicles or allows easy egress 9 Powering...

Page 8: ...ate sheaths i e 2 x 2 wires not 4 core 100263 supplied 2 1 1 2 3 4 Close Beam approx 200mm Close Beam approx 700mm Open beam any height Jumper must be off default Jumper must be installed To install s...

Page 9: ...nal that the lamp converts to a flashing signal Cable cross section 0 5 mm2 AWG20 or greater Voltage 24 V DC 24 VDC OUTPUT For relay infrared sensors or other devices e g receivers max 500 mA Do not u...

Page 10: ...sensor enables the automatic reversing of the gate if an obstacle is detected and increasing the gates sensitivity and safety NOTE The sensor is only active during the drive s fast run cycle and is sw...

Page 11: ...stem can be used by adding a relay accessory TRIM POTS POTENTIOMETER PT1 TRIM POT 1 BRAKE When the gate reaches its limit switch the drive shuts down Depending on weight and function of the gate it ma...

Page 12: ...o open until released i e press and hold to open the gate Closing input 2 will cause the gate to close until released i e press and hold to close the gate No radio or safety functions work in this mod...

Page 13: ...rminals 7 10 Input trigger 1 normally open Terminals 8 10 Input trigger 2 normally open Terminals 9 10 Emergency stop push button NC must be bridged if no switch connected Terminals 11 12 Gate monitor...

Page 14: ...conds before the limit switch is reached This option can be selected via dip switch page 11 NOTE If the gate closes instead of opening dip switch 7 must be moved to the other position Turn the power o...

Page 15: ...connections The gate opener stops suddenly and then restarts only after a lengthy pause If the gate is operated constantly the motor will reach its cut off temperature protective facility as the gate...

Page 16: ...larity terminals 14 15 Swap and cables PE OVERRIDE If a safety edge or loop detector is fitted and the PE beams are not used the PE terminals must be terminated to com as illustrated below Factory ins...

Page 17: ...ted to Lamp output 1 used unused Cable Colour Colour connected to Safety edge Device Cable Colour 20 Colour 21 Safety Inputs Open used unused Device Cable Colour 16 Colour 19 Close used unused Device...

Page 18: ...tch MGS Magnetic Switch MGS 041SLG 0054 041SLG 0054 Lock Key Lock Key 041SLG 0054K 041SLG 0054K Release Key Piece Release Key Piece 041SLG 0176 041SLG 0176 Gear Sprocket MGS300 500 Gear Sprocket MGS30...

Page 19: ...erlin MGS series gate operator Unit that it is free from defects in material and or workmanship for a period of 2 YEARS from the date of first purchase from the Seller Please retain your proof of purc...

Page 20: ...20 Chamberlain ANZ 2008 all rights reserved 709450...

Reviews: