background image

041S

LG

-125S

A

041SLG-0125S

041SLG-0125S A

A

Bag Nuts & W

Bag Nuts & Washers

ashers

041SLG-0152SA

041SLG-0152SA
Stator & Housing Assy MGS300/500

Stator & Housing Assy MGS300/500
041SLG-0153SA

041SLG-0153SA
Stator & Housing Assy MGS1000

Stator & Housing Assy MGS1000

041SLG-0078

041SLG-0078
Inside Control Board Box Cover

Inside Control Board Box Cover

041SLG-0079

041SLG-0079
Inside Control Board Box

Inside Control Board Box
Lower Part 

Lower Part 

041SLG-0175SA

041SLG-0175SA
Service Gear Set MGS300/500 

Service Gear Set MGS300/500 
041SLG-0176SA

041SLG-0176SA

Service Gear Set MGS1000

Service Gear Set MGS1000

041SLG-0068

041SLG-0068

Magnetic Switch MGS

Magnetic Switch MGS

041SLG-0054

041SLG-0054

Lock & Key

Lock & Key

041SLG-0054K

041SLG-0054K

Release Key / Piece

Release Key / Piece

041SLG-0176

041SLG-0176

Gear Sprocket MGS300/500

Gear Sprocket MGS300/500
041SLG-0179

041SLG-0179
Gear Sprocket MGS1000

Gear Sprocket MGS1000

041SLG-0058

041SLG-0058
Motor Mounting Plate 

Motor Mounting Plate 

041SLG-0193

041SLG-0193

Drive Sprocket Module4

Drive Sprocket Module4

041SLG-0198

041SLG-0198
PLASTIC COVER

PLASTIC COVER

Capacitors

Capacitors
 
8mf MGS300 041F091

8mf MGS300 041F091
10mf MGS500 041F096 

10mf MGS500 041F096 
16mf MGS1000 041F0096-16

16mf MGS1000 041F0096-16

041SLG-053M

041SLG-053M
Rack Magnets 1,2 and brackets

Rack Magnets 1,2 and brackets

041ASLG-0362

041A5456 (433MHz)

041ASLG-1005SA

041ASLG-1005SA

041ASLG-1004SA

041ASLG-1004SA

041ASLG-1150SA

041ASLG-1150SA

041SLG60054

041ASLG-00920

Summary of Contents for Merlin MGS1000

Page 1: ...300 MGS500 AND MGS1000 and CB22 CONTROL BOARD Chamberlain Australia Pty Ltd PO Box 1446 Lane Cove NSW 1595 Phone toll free 1800 638 234 Chamberlain New Zealand Ltd PO Box 100 221 North Shore 0745 Phon...

Page 2: ...dren Never allow children to play near an operational gate After installation is complete a final test of ALL functions and SAFETY systems must be carried out Where safety devices are installed it is...

Page 3: ...des poorly is likely to need a stronger drive than a heavy smooth sliding gate NOTE Gate weight is only an approximate indicator the actual relevance of which can vary greatly Climatic conditions Gate...

Page 4: ...re that a conduit is installed before adding the concrete and that the exit point for the conduit is on the correct side of the base plate in relation to the motor The plate has two recesses ensure th...

Page 5: ...arance between drive and rack Mounting the Motor Hand tighten one of the nuts provided onto each of the four posts tighten to about 15mm from the base of the plate then place a washer provided onto ea...

Page 6: ...lex nut provided Installing the magnet and bracket for nylon rack Identify your start and stop limit Fit the bracket over the rack and tighten the screws Install the start and stop magnets as outlined...

Page 7: ...injury to person whilst the gate is moving not required if the gate recess is enclosed 9 Induction loop for safety or exit optional protects against damage to vehicles or allows easy egress 9 Powering...

Page 8: ...ate sheaths i e 2 x 2 wires not 4 core 100263 supplied 2 1 1 2 3 4 Close Beam approx 200mm Close Beam approx 700mm Open beam any height Jumper must be off default Jumper must be installed To install s...

Page 9: ...nal that the lamp converts to a flashing signal Cable cross section 0 5 mm2 AWG20 or greater Voltage 24 V DC 24 VDC OUTPUT For relay infrared sensors or other devices e g receivers max 500 mA Do not u...

Page 10: ...sensor enables the automatic reversing of the gate if an obstacle is detected and increasing the gates sensitivity and safety NOTE The sensor is only active during the drive s fast run cycle and is sw...

Page 11: ...stem can be used by adding a relay accessory TRIM POTS POTENTIOMETER PT1 TRIM POT 1 BRAKE When the gate reaches its limit switch the drive shuts down Depending on weight and function of the gate it ma...

Page 12: ...o open until released i e press and hold to open the gate Closing input 2 will cause the gate to close until released i e press and hold to close the gate No radio or safety functions work in this mod...

Page 13: ...rminals 7 10 Input trigger 1 normally open Terminals 8 10 Input trigger 2 normally open Terminals 9 10 Emergency stop push button NC must be bridged if no switch connected Terminals 11 12 Gate monitor...

Page 14: ...conds before the limit switch is reached This option can be selected via dip switch page 11 NOTE If the gate closes instead of opening dip switch 7 must be moved to the other position Turn the power o...

Page 15: ...connections The gate opener stops suddenly and then restarts only after a lengthy pause If the gate is operated constantly the motor will reach its cut off temperature protective facility as the gate...

Page 16: ...larity terminals 14 15 Swap and cables PE OVERRIDE If a safety edge or loop detector is fitted and the PE beams are not used the PE terminals must be terminated to com as illustrated below Factory ins...

Page 17: ...ted to Lamp output 1 used unused Cable Colour Colour connected to Safety edge Device Cable Colour 20 Colour 21 Safety Inputs Open used unused Device Cable Colour 16 Colour 19 Close used unused Device...

Page 18: ...tch MGS Magnetic Switch MGS 041SLG 0054 041SLG 0054 Lock Key Lock Key 041SLG 0054K 041SLG 0054K Release Key Piece Release Key Piece 041SLG 0176 041SLG 0176 Gear Sprocket MGS300 500 Gear Sprocket MGS30...

Page 19: ...erlin MGS series gate operator Unit that it is free from defects in material and or workmanship for a period of 2 YEARS from the date of first purchase from the Seller Please retain your proof of purc...

Page 20: ...20 Chamberlain ANZ 2008 all rights reserved 709450...

Reviews: