Separate table for setting the operating modes
A momentary pulse across 7
and 10 will:
• open the gate if closed,
• stop the gate if in motion,
( a second pulse will
re- open the gate).
• close gate if open
Standard
(Start, stop, close).
Standard & pedestrian function
Separate inputs
Start, stop, step by step. separate
close input.
A momentary pulse across 7 and
10 will:
Open the gate, a pulse whilst
opening will stop the gate,
another pulse will start the gate
opening again etc.
A momentary pulse across 8 and 10
will:
• be ignored if the gate is closed.
• close the gate if open, further
pulses will start and stop the gate
until the close limit is reached.
If Gate has been triggered to
close by input 2 a pulse on input
1 will stops and start the gate
detailed above.
Car park
A momentary pulse will:
• opens the gate ignoring any
subsequent trigger pulses
• reset the open (rest) time if re-
triggered whilst open.
• open the gate if closing.
A momentary pulse will:
• open the gate partially for
pedestrian access, ignoring
subsequent pulse whilst opening.
• Once open a second pulse will
close the gate.
• if a pulse is generated whilst
closing the gate will reopen.
No self-hold (hold to run)
Closing input 1 will cause the
gate to open until released i.e
press and hold to open the gate.
Closing input 2 will cause the gate
to close until released i.e press
and hold to close the gate.
No radio or safety functions
work in this mode.
Limit switches are active
DIP1
ON
OFF
ON
ON
OFF
DIP2
ON
ON
ON
OFF
OFF
DIP3
OFF
OFF
ON
OFF
OFF
Control input 1
(terminal 7 and 10)
Control input 2
(terminal 8 and 10)
Note:
When changing DIP switches the unit must be powered down as the DIP switches have a digital memory.
The Control board will operate according to the way the dip switches were the last time the board received power.
OPERATIONAL NOTE:
If safety beams are damaged or safety terminals are not bridged the gate will still operate
in the “hold to run” mode.
A momentary pulse across 8 and
10 will:
• activate the motor for 10
seconds to allow pedestrian
access i.e a partial opening.
A second pulse is required to close
the gate. If closing a further pulse
will partially re-open the gate for
pedestrians
A momentary pulse across 8 and
10 will:
• activate the motor for 10
seconds to allow pedestrian
access i.e a partial opening.
A second pulse is required to close
the gate. If closing a further pulse
will partially re-open the gate for
pedestrians
A momentary pulse across 7
and 10 will:
• open the gate if closed,
• close gate if opening
* close gate if open (at rest)
No radio or safety functions
work in this mode.
Limit switches are active