Configuration options
The control board has 5 operational modes. The desired
program is set using the dip switch “ON” or “OFF”.
Assigned to various drive operating modes. (see
separate table)
Soft stop (slow run) is active The soft stop is
activated 2 seconds before the limit switch is
reached. The drive stops only when the limit
switches have been reached or as soon as the
maximum soft stop phase (10 seconds) has
expired.
Soft stop (slow run) is disabled.
The drive shuts down immediately in both
directions OPEN/CLOSED as soon as the limit
switches have been reached.
Setting for Chamberlain failsafe
photocells (770ANZ/771ANZ), complies with
EN60335-2-103
Setting for Chamberlain photocells (100263) or
others
(Supplied with MGS)
Preflash function of flashing light 2 seconds
before the drive starts.
Preflash function disabled
see B
see A
Connection option for a
gate monitor (24V/3W)
Status:
Permanently off = gate closed
Flashes = gate moving in OPEN or CLOSED
direction
Permanently on = gate open
A yard lighting system can be used by adding a
relay (accessory).
TRIM POTS (POTENTIOMETER)
PT1 (TRIM POT 1): BRAKE
When the gate reaches its limit switch, the drive shuts
down. Depending on weight and function of the gate, it
may continue to move on a bit further before stopping.
The brake function is for the active braking of the gate
in order to minimise this additional movement. Left stop
= brake OFF.
PT2 (TRIM POT 2): AUTOMATIC CLOSING (TIMER
TO CLOSE)
Sets the delay between when the gate is opened and
when it closes (0-150 sec) adjustable.
Only possible if
a photocell is connected (771ANZ/770ANZ).
(Not possible for self-hold and channel separation)
PT3 (TRIMMING POTENTIOMETER 3): FORCE
SETTING
Defines the amount of force exerted by the motor. The
required force depends on weight and function of the
gate.
PT4 (TRIMMING POTENTIOMETER 4): RPM
SENSOR
See RPM sensor description
Not active for “Slow run”
1
2
OFF
1
2
ON
A
NOTE: Power must be disconnected
to make changes to the DIP switches, if not
changes will not be accepted
NOTE: Power must be disconnected
to make changes to the TRIM POTS, if not
changes will not be accepted
DIP 1
DIP 2
DIP 3
DIP 4
DIP 5
DIP 6
DIP 7
DIP 8
On
Off
On
Off
On
Off
On
Off
On
Off
On
Off
On
Off
On
Off
11