TEACHING / DELETING THE HAND-HELD
TRANSMITTERS
Channel 1: (up to 128 users)
ADD
: Press button CH1. The LED “Learn1” lights up red.
Press one of the transmitterʼs button for approx. 5
seconds. The LED “Learn 1” flashes.
DELETE
: Press and hold the CH1 button down until the
LED goes out.
(WARNING THIS DELETES ALL CH1 MEMORY)
Channel 2 Pedestrian function if configured
(up to 128 users)
Press button CH2. The LED “Learn2” lights up red. Press
one of the transmitterʼs buttons for approx. 5 seconds.
The LED “Learn 2”
DELETE
: Press and hold the CH2 button down until the
LED goes out.
(WARNING THIS DELETES ALL CH2 MEMORY)
RPM SENSOR (OPTIONAL) 041ACOM17001
This optional RPM sensor may be installed onto your
MGS motor simply by plugging the pre-made cable
into CN2 and fastening the sensor in place. The
sensor enables the automatic reversing of the gate if
an obstacle is detected and increasing the gates
sensitivity and safety.
NOTE: The sensor is only active during the driveʼs fast
run cycle and is switched off for the soft stop (slow
run).
RADIO MODULE (factory fitted)
Your receiver module was fitted during manufacture. If
the unit has dislodged during transportation or needs to
be replaced, please insert the module the 801221
(433.92 MHz module into the slots CN4/CN5 as shown.
learn remotes
ELECTRIC LOCK (OPTIONAL) 203285 (12V)
An electric lock can be connected to the control board
using the connector CN1.
Alternatively a small relay can be triggered from the
lamp1 output where a magnetic lock is used.
E-LOCK MUST NOT EXCEED 500ma.
Do not use Solid core cables
Do not place high and low voltage cables in
the same conduit.
Ensure all cabling complies with local
electrical standards.
FOR SAFETY: ENSURE GATE MOTOR IS
DISENGAGED BEFORE LEARNING
TRANSMITTERS INTO YOUR MOTOR
10